AR-M550 (serv.man14). (7) Settings and adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 38

Read Sharp AR-M550 (serv.man14) Service Manual online

AR-M550/M620  SETTING AND ADJUSTMENTS  7 - 38
3) Enter the number that corresponds to the following adjustment
item using the numeric keypad.  (Choose from numbers 0 to 5.)
• Auto mode
• Manual mode (print density adjustment level)
For manual mode, select the number that corresponds to the
image density adjustment level (1 to 5).  (Choose from numbers 1
to 5.)
6) Press the Start key
7) Enter the image density adjustment value. 
8) Press the P or Start key
Scanned images must be visually checked to ensure the post-adjust-
ment image density.
1) Go through the modes specified in Simulation 46-27.
2) Using the numeric keypad, select the number that corresponds to
the scan mode for which to make adjustments. 
4) Press the Start key
5) Adjust the gamma by entering an appropriate value through the
numeric keypad. 
A larger value provides larger gamma gradient and higher image
contrast.
6) Press the Start key
This applies the adjustment value. 
Scanned images must be visually checked to ensure the post-adjust-
ment image gamma.
(Common image quality adjustment items for all of copy, scan, 
and fax modes)
This adjustment is needed in the following situations: 
• The CCD unit has been replaced. 
• U2 trouble has occurred. 
• The MFP control PWB has been replaced.
• The EEPROM on the MFP control PWB has been replaced.
• The scanner control PWB has been replaced.
• The EEPROM on the scanner control PWB has been replaced.
• One or more parts of the scanner (reading) section have been
replaced. 
• The CIS unit has been removed. 
• The CIS unit has been replaced. 
• The SPF unit has been removed. 
• The SPF unit has been replaced. 
1) Go through the modes specified in Simulation 46-20.
Select other than 0 - 5, and 
press [START] key.
Press [START] key, or press 
[CUSTOM SETTINGS] key.
Item
Set 
range
Default
0
AUTO
Auto
0 - 99
50
1
1.0
Exposure level 1
2
2.0
Exposure level 2
3
3.0
Exposure level 3
4
4.0
Exposure level 4
5
5.0
Exposure level 5
ADJ 11F
Adjust the image gamma in scanner 
mode
Item
1
OC_Fine.HT
Fine text (Half-tone) (OC)
2
OC_SFine.HT
Super fine (Half-tone) (OC)
3
OC_UFine.HT
Ultra fine (Half-tone) (OC)
4
SPF_Fine.HT
Fine text (Half-tone) (SPF)
5
SPF_SFine.HT
Super fine (Half-tone) (SPF)
6
SPF_UFine.HT
Ultra fine (Half-tone) (SPF)
7
CIS_Fine.HT
Fine text (Half-tone) (CIS)
8
CIS_SFine.HT
Super fine (Half-tone) (CIS)
9
CIS_UFine.HT
Ultra fine (Half-tone) (CIS)
1
SIMULATION 46-22
EXP.LEVEL SETUP SCANNER(NORMAL). SELECT 0-5, AND PRESS
START.
0.AUTO 
50
 1.1.0 
50
    2.2.0 
50
3.3.0 
50
  4.4.0 
50
    5.5.0 
50
50
SIMULATION 46-22
EXP.LEVEL SETUP SCANNER(NORMAL), INPUT VALUE 0-99, AND
PRESS START.
0.AUTO
SIMULATION 46-27
GAMMA SETUP(SCNNER), SELECT 1-9, AND PRESS START.
1.OC_Fine.HT 
64
   2.OC_SFine.HT 
64
   3.OC_UFine.HT 
64
4.SPF_Fine.HT 
64
  5.SPF_SFine.HT 
64
  6.SPF_UFine.HT 
64
7.CIS_Fine.HT 
64
  8.CIS_SFine.HT 
64
  9.CIS_UFine.HT 
64
ADJ 12
Common image quality 
adjustments for all of copy, scan, 
and fax modes
Adjustment items
Simulation for adjustment
Original table mode/SPF mode image 
density correction
46-20
(Auto mode operation spec setting for 
copy, scan, and fax)
46-19
ADJ 12A
Correct the image density in original 
table mode/SPF mode
Page of 44
Display

Click on the first or last page to see other AR-M550 (serv.man14) service manuals if exist.