AR-M351U, AR-M451U (serv.man17). Simulations - Sharp Copying Equipment Service Manual (repair manual). Page 78

Read Sharp AR-M351U / AR-M451U (serv.man17) Service Manual online

AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 78
Operation/Procedure
1) Select the number corresponding to the output mode with 10-
key.
2) Press [START] key.
The signal is sent in the send level set with the soft switch.
When the number is entered during execution, the kind of signal
can be changed.
When [CUSTOM SETTINGS] key is pressed during execution, the
operation is stopped.
Operation/Procedure
1) Enter the dial number with 10-key.
Use 10-key, [*] key, and [#] key to enter the number. The
upper limit is 20 digits.
When [CLEAR] key is pressed, the mode returns to the initial
state.
2) Press [START] key.
Operation/Procedure
1) Enter 0 with 10-key.
2) Press [START] key. 
The dial signal is outputted.
Same display 
Select 3 and press [START] key.
66-12
Purpose
Operation test/Check
Function
(Purpose)
Used to check the output operation of FAX G3 
mode 300bps. (Used to check the operation of 
MODEM.) An output is send at the send level set 
by the soft switch. (Only when FAX is installed)
Section
FAX
Item
Operation
1
NO SIGNAL
No signal 
4
00000
00000
2
11111
11111
5
010101
010101
3
11110
11110
6
00001
00001
SIMULATION 66-11
300bps SIGNAL OUTPUT.(LEVEL MAX)  SELECT 1-6, AND PRESS
START.
1. NO SIGNAL  2. 11111  3. 11110  4. 00000
5. 010101     6. 00001
SIMULATION 66-11
300bps SIGNAL OUTPUT.(LEVEL MAX)  SELECT 1-6, AND PRESS
START.
EXECUTING···.
1. NO SIGNAL  2. 11111  3. 11110  4. 00000
5. 010101     6. 00001
1
1
Press [START] key. 
Press [CUSTOM SETTINGS] key
SIMULATION 66-11
300bps SIGNAL OUTPUT.(LEVEL MAX)  SELECT 1-6, AND PRESS
START.
EXECUTING···.
1. NO SIGNAL  2. 11111  3. 11110  4. 00000
5. 010101     6. 00001
3
Press [CUSTOM SETTINGS] key.
Same display
Select 3 and press [START] key.
66-13
Purpose
Setting
Function
(Purpose)
Used to enter (set) the number of FAX dial signal 
output test. (The dial number set by this simulation 
is outputted when the dial signal output test is 
made by SIM 66-14  - 16. ) (Only when FAX is 
installed)
Section
FAX
Item
Data
66-14
Purpose
Setting/Operation test/Check
Function
(Purpose)
Used to set the make time in the FAX pulse dial 
mode (10pps) and to test the dial signal output. 
(The dial number signal set by SIM 66-13 is 
outputted.) Used to check troubles in dialing and 
to check the operation. (Only when FAX is 
installed)
Section
FAX
Item
Operation
SIMULATION 66-12
300bps SIGNAL OUTPUT.(SOFT SW.)  SELECT 1-6, AND PRESS
START.
1. NO SIGNAL  2. 11111  3. 11110  4. 00000
5. 010101     6. 00001
SIMULATION 66-12
300bps SIGNAL OUTPUT.(SOFT SW.)  SELECT 1-6, AND PRESS
START.
EXECUTING···.
1. NO SIGNAL  2. 11111  3. 11110  4. 00000
5. 010101     6. 00001
1
1
Press [START] key.
Press [CUSTOM SETTING] key.
SIMULATION 66-12
300bps SIGNAL OUTPUT.(SOFT SW.)  SELECT 1-6, AND PRESS
START.
EXECUTING···.
1. NO SIGNAL  2. 11111  3. 11110  4. 00000
5. 010101     6. 00001
2
Press [CUSTOM SETTINGS] key.
SIMULATION 66-13
DIAL TEST NUMBER SETTING.      0-9:[0-9], *:[*], #:[#]
INPUT NUMBER AND PRESS START.
0123456789*#01234567
Page of 88
Display