AR-M351U, AR-M451U (serv.man17). Simulations - Sharp Copying Equipment Service Manual (repair manual). Page 73

Read Sharp AR-M351U / AR-M451U (serv.man17) Service Manual online

AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 73
Operation/Procedure
Touch the four cross marks (+) sequentially. The coordinates of
pressed positions are set.
When the coordinates setting is completed normally, the display
turns gray. When all the four points are set, the display returns to
the normal state.
Operation/Procedure
When the touch panel is touched, the X and Y coordinate values
of the touched point and the coordinate values of the specified
point are displayed. The coordinate values set with SIM 65-1 are
used as the reference.
Operation/Procedure
Setting of soft switches other than SW1 can be changed and
checked. 
1) Enter the soft switch number to be checked or changed with
10-key.
The current set state is displayed.
2) Enter the number corresponding to the bit to be changed with
10-key.
(Example) When the bit of 5 is to be changed, enter 5.
The set value of 1/0 is alternatively changed every time when
the target key is pressed.
3) After completion of setting of all the bits, press [START] key.
Operation/Procedure
1) Set the destination code with 10-key.
The codes other than the above are recognized as Japan.
2) Press [START] key.
3) The confirmation menu of YES/NO of clear is displayed.
Select one.
4) Press [START] key. 
The soft switch (except for the adjustment values) is cleared
according to the destination selected in procedure 1).
NOTE: When the FAX BOX is not installed, initialization including
the adjustment value is performed. (The adjustment value
is stored in the FAX BOX.)
65
65-1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the touch panel (LCD display 
section) detection position.
Section
Operation (Display/Operation key)
Item
65-2
Purpose
Adjustment/Setup/Operation data output/Check 
(Display/Print)
Function
(Purpose)
Used to check the result of the touch panel (LCD 
display) detection position adjustment. (The 
coordinates are displayed.)
Section
Operation (Display/Operation key)
Item
66
66-1
Purpose
Setting
Function
(Purpose)
Used to change and check the FAX soft switch 
functions. (Used to change and check the 
functions provided for the FAX soft switches.) 
(Only when FAX is installed)
Section
FAX
Item
SIMULATION 65-1
SIMULATION 65-2
400
500
600
40
100            200            300
100
140
600
180
200
Press [START] key.
Press [CUSTOM SETTINGS] key or [START] key.
66-2
Purpose
Data clear
Function
(Purpose)
Used to clear the FAX soft switch function data 
and to set to the default. (Excluding the 
adjustment values.) (Only when FAX is installed)
Section
FAX
Item
Data
Japan
0 0 0 0 0 0 0 0
Finland
0 0 1 1 1 1 0 0
U.S.A.
1 0 1 1 0 1 0 1
Norway
1 0 0 0 0 0 1 0
Australia
0 0 0 0 1 0 0 1
Denmark
0 0 1 1 0 0 0 1
U.K.
1 0 1 1 0 1 0 0
Netherlands
0 1 1 1 1 0 1 1
France
0 0 1 1 1 1 0 1
Italy
0 1 0 1 1 0 0 1
Germany
0 0 0 0 0 1 0 0
Switzerland
1 0 1 0 0 1 1 0
Sweden
1 0 1 0 0 1 0 1
Austria
0 0 0 0 1 0 1 0
Newzealand
0 1 1 1 1 1 1 0
Indonesia
0 1 0 1 0 1 0 0
China
0 0 1 0 0 1 1 0
Thailand
1 0 1 0 1 0 0 1
Singapore
1 0 0 1 1 1 0 0
Malaysia
0 1 1 0 1 1 0 0
TW
1 1 1 1 1 1 1 0
India
0 1 0 1 0 0 1 1
Other1
1 1 1 1 1 1 0 1
Philippines
1 0 0 0 1 0 0 1
Other2
1 1 1 1 1 1 0 0
Hongkong
0 1 0 1 0 0 0 0
Ohter3
1 1 1 1 1 0 1 1
1
YES
FAX soft SW is cleared.
2
NO
Not cleared.
SIMULATION 66-1
FAX SOFT SW. SETTING. SELECT 2-120, AND PRESS START.
SIMULATION 66-1
FAX SOFT SW. SETTING. INPUT DATA No(1-8), AND PRESS
START.
     SOFT SW-2:
1  2  3  4  5  6  7  8
Page of 88