AR-M351U, AR-M451U (serv.man17). Simulations - Sharp Copying Equipment Service Manual (repair manual). Page 4

Read Sharp AR-M351U / AR-M451U (serv.man17) Service Manual online

AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 4
24
6
Used to reset the copy counter.
7
Used to clear the OPC drum counter. (Perform 
this simulation when the OPC drum is replaced.)
9
Used clear the printer mode print counter and the 
self print mode print counter.
10
Used to clear the FAX counter. (Only when FAX 
is installed)
11
Used to reset the OPC drum rotation time, and 
the DV unit rotation time counter. The developer 
counter in the DV unit installed is reset.
15
Used to clear the counters related to the scan 
mode and the internet FAX mode.
25
1
Used to check the operations of the developing 
section (toner concentration, humidity and toner 
concentration sensor, humidity sensor, 
temperature sensor output can be monitored.)
2
Used to make the initial setting of toner 
concentration when replacing developer.
26
3
Used to set the specifications of the auditor. 
Setting must be made according to the auditor 
use conditions.
5
Used to set the count mode of the total counter 
and the maintenance counter.
6
Used to set the specifications (paper, document 
detection, etc.) of the destination.
10
Used to set the network scanner trial mode.
18
Used to set YES/NO of toner save operation. 
(This function is valid only in Japan and UK 
versions. (Depends on the destination setting of 
SIM26-6.) For the other destinations, the same 
setting can be made by the user program P22.)
30
Used to set the operation mode conforming to the 
CE mark (Europe safety standards). (Conforming 
to soft start when driving the fusing heater lamp.)
35
Used to set whether the same continuous 
troubles are displayed as one trouble or the 
series of troubles with SIM 22-4 when the same 
troubles occur continuously.
38
Used to set CONTINUE/STOP of printing when 
maintenance timing is over and the count value 
reaches 110% of replacement timing (life). 
41
Used to set the automatic magnification ratio 
selection (AMS) in the pamphlet mode.
50
Black-White reverse YES/NO setting
52
Used to set whether non-print paper (insertion 
paper, cover paper) (blank image print paper) is 
counted up or not.
68
Used to set ENABLE/DISABLE of the CA key 
cancel function of print stop.
27
1
Used to set the specifications for operations in 
case of communication trouble between the host 
computer and MODEM (machine side). (When 
communication trouble occurs between the host 
computer MODEM and the machine, the self diag 
display (U7-00) is printed and setting for inhibition 
of print or not is made.)
5
Used to enter the machine tag No. (This function 
allows to check the tag No. of the machine with 
the host computer.)
30
1
Used to check the operation of sensors and 
detectors in other than the paper feed section and 
the operations of the related circuits.
2
Used to check the operation of sensors and 
detectors in the paper feed section and the 
related circuits.
Code
Function (Purpose)
Main
Sub
40
1
Used to check the operation of the manual feed 
tray paper size detector and the related circuit. 
(The operation of the manual feed tray paper size 
detector can be monitored with the LCD display.)
2
Used to adjust the manual paper feed tray paper 
width detector detection level.
7
Used to enter the manual paper feed tray paper 
width adjustment value.
11
Used to check the multi-purpose tray width 
detection adjustment value.
12
Used to check the multi-purpose tray width 
detection adjustment value.
41
1
Used to check the operation of the document size 
sensor and the related circuit. (The operation of 
the document size sensor can be monitored with 
the LCD display.)
2
Used to adjust the document size sensor sensing 
level.
3
Used to check the operation of the document size 
sensor and the related circuit. (The document 
size sensor output level can be monitored with 
the LCD display.)
43
1
Used to set the fusing temperature in each 
operation mode.
44
1
Used to set enable/disable of correction 
operations in the image forming (process) 
section.
9
Used to check the data related to the image 
forming section correction (process correction) 
result (corrected main charger grid voltage, the 
developing bias voltage, and the laser power 
voltage in each print mode). (This simulation 
allows to check that correction is performed 
normally or not.)
14
Used to check the output level of the temperature 
sensor and the humidity sensor.
16
Used to check the toner concentration control 
data.
46
2
Used to adjust the copy density in all the copy 
modes (Auto, Text, Text/Photo, and Photo mode).
9
Used to adjust the print density for each density 
level (display value) in the copy mode (binary - 
Text mode). An optional print density can be set 
for each density level (display value).
10
Used to adjust the print density for each density 
level (display value) in the copy mode (binary - 
Text/Photo mode). An optional print density can 
be set for each density level (display value).
11
Used to adjust the print density for each density 
level (display value) in the copy mode (binary - 
Photo mode). An optional print density can be set 
for each density level (display value).
12
Used to adjust the print density in the FAX mode 
(all modes). 
13
Used to adjust the print density in the FAX mode 
(each normal mode). (Only when FAX is 
installed.)
14
Used to adjust the print density in the FAX mode 
(each fine mode). (Only when FAX is installed.)
15
Used to adjust the print density in the FAX mode 
(each super fine mode). (Only when FAX is 
installed.)
16
Used to adjust the print density in the FAX mode 
(each ultra fine mode). (Only when FAX is 
installed.)
17
Used to set the gain in shading correction.
Code
Function (Purpose)
Main
Sub
Page of 88
Display

Click on the first or last page to see other AR-M351U / AR-M451U (serv.man17) service manuals if exist.