AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 13
*1: Displayed when OPTION of multi-purpose only.
*2: Displayed when manual feed OPTION is added.
Operation/Procedure
1) Select the number corresponding to the target of operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1 operates.
Press [CUSTOM SETTINGS] key to stop the operation.
Operation/Procedure
1) Select the number corresponding to the operating condition of
aging with 10-key.
The combined mode of 0 - 6 mode and 10, 20, or 30 mode can
be set.
be set.
In that case, the number corresponding to one of 0 - 6 mode
and the number corresponding to one of 10, 10, and 30 mode
are added and the sum number is entered.
and the number corresponding to one of 10, 10, and 30 mode
are added and the sum number is entered.
2) Press [START] key.
The condition selected in procedure 1) is set.
The setting of this simulation is kept valid until the power is turned
off.
off.
18*1
MCLUM
MP tray lift-up motor signal
19*2
MPFS
Manual paper feed solenoid signal
20*2
MPFC
Manual paper feed clutch signal
21*2
MSS
Manual paper feed gate solenoid
Press [START] key, and the
operation is started.
operation is started.
Press [CUSTOM SETTINGS] key, and the
operation is stopped immediately or after
repeating the operation several times.
operation is stopped immediately or after
repeating the operation several times.
6-2
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of each fan motor
and its control circuit.
and its control circuit.
Section
Other
Item
Operation
1
Fan motor high speed
2
Fan motor low speed
3
Cooling fan motor (Controller/HDD)
Press [START] key, and the operation
is started.
is started.
Press [CUSTOM SETTINGS] key, and
the operation is stopped.
the operation is stopped.
SIMULATION 6-1
FEED OUTPUT CHECK. SELECT 1-22, AND PRESS START.
1.MSWPR 2.HLPR 3.DCPR 4.MM 5.DM 6.DSB_FW
7.DSB_RV 8.CPFC 9.RRC 10.TRC 11.FGS_FIN
12.LUM 13.TRC_DSK 14.PSPS
15.MCM 16.MCPCL 17.MCFCL 18.MCLUM
19.MPFS 20. MPFC 21.MSS 22.MSWS
2
SIMULATION 6-1
FEED OUTPUT CHECK. EXECUTING....
1.MSWPR 2.HLPR 3.DCPR 4.MM 5.DM 6.DSB_FW
7.DSB_RV 8.CPFC 9.RRC 10.TRC 11.FGS_FIN
12.LUM 13.TRC_DSK 14.PSPS
15.MCM 16.MCPCL 17.MCFCL 18.MCLUM
19.MPFS 20.MPFC 21.MSS 22.MSWS
2
SIMULATION 6-2
FAN MOTOR CHECK. SELECT 1-3, AND PRESS START.
1.FMHi
2.FMLo
3.CFM-ICU/HDD
2
SIMULATION 6-2
FAN MOTOR CHECK..
2.FMLo
2
7
7-1
Purpose
Setting
Function
(Purpose)
(Purpose)
Used to set the operating conditions of aging.
Section
Item
Operation
0
NO MISS FEED DETECTION No jam detection
1
AGING
Aging mode
2
AGING/NO MISS FEED
DETECTION.
DETECTION.
No jam detection, aging
mode
mode
3
AGING/NO MISS FEED
DETECTION/NO WARM UP/
NO TEMPERATURE
CONTROL.
DETECTION/NO WARM UP/
NO TEMPERATURE
CONTROL.
No jam detection/ no warm-
up/ no fusing temperature
control, aging mode
up/ no fusing temperature
control, aging mode
4
NO WARM UP.
No warm-up
5
AGING/INTERVAL.
Intermittent aging mode
6
AGING/INTERVAL/NO MISS
FEED DETECTION.
FEED DETECTION.
No jam detection
intermittent aging mode
intermittent aging mode
+10 NO PROCESS UNIT CHECK. Above +10: No process unit
(including the developing
unit) detection
unit) detection
+20 NO SHADING.
Above +20: No shading
+30 NO PROCESS UNIT CHECK/
NO SHADING.
Above +30: No process unit
detection /no shading
detection /no shading
Press [START] key to start registration and operation.
The operation mode is kept until the power is turned off or setting is made again.
The operation mode is kept until the power is turned off or setting is made again.
SIMULATION 7-1
AGING TEST SETTING. SELECT 0-36, AND PRESS START.
0.NO MISS FEED DETECTION
1.AGING
2.AGING/NO MISS FEED DETECTION.
3.AGING/NO MISS FEED DETECTION/
NO WARM UP/NO TEMPERATURE CONTROL.
4.NO WARM UP.
5.AGING/INTERVAL.
6.AGING/INTERVAL/NO MISS FEED DETECTION.
+10:NO PROCESS UNIT CHECK.
+20:NO SHADING.
+30:NO PROCESS UNIT CHECK/NO SHADING.
2