AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 16
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated.
Press [CUSTOM SETTINGS] key to stop the operation.
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played.
played.
The active sensors and detectors are highlighted.
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated for 10sec.
Press [CUSTOM SETTINGS] key to stop the operation.
NOTE: Never execute this simulation with toner in the toner hop-
per.
If executed, excessive toner will enter the developing sec-
tion. Be sure to remove the toner motor from the toner hop-
per before execution.
If executed, excessive toner will enter the developing sec-
tion. Be sure to remove the toner motor from the toner hop-
per before execution.
Press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key.
Or after 30sec output.
Or after 30sec output.
9
9-1
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check and adjust the operation of the load
(clutch/solenoid) in the duplex section and the
control circuit.
(clutch/solenoid) in the duplex section and the
control circuit.
Section
Duplex
Item
Operation
1
ADMEN1
ADU motor 1 control signal
2
ADMEN2
ADU motor 2 control signal
3
DGS
ADU gate solenoid
Press [START] key.
Press [CUSTOM SETTINGS] key to
stop the operations.
stop the operations.
SIMULATION 8-17
1
TRANSFER ROLLER SETTING. SELECT 1-3, AND PRESS START.
1.SHV FRONT
160
2.SHV BACK
160
3.THV-
780
SIMULATION 8-17
TRANSFER ROLLER SETTING. INPUT VALUE, AND PRESS START.
1.FRONT (0-240)
160
SIMULATION 8-17
TRANSFER ROLLER SETTING. EXECUTING···.
1.FRONT(0-240)
160
SIMULATION 9-1
ADU OUTPUT CHECK. SELECT 1-3, AND PRESS START.
1.ADMEN1
2.ADMEN2
3.DGS
1
SIMULATION 9-1
ADU OUTPUT CHECK. EXECUTING···.
1.ADMEN1
2.ADMEN2
3.DGS
1
9-2
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of the sensors and
detectors in the duplex section and its control
circuit.
detectors in the duplex section and its control
circuit.
Section
Duplex
Item
Operation
ADUSET
ADU installation detection
DSW_D
ADU cabinet open detection
AINPD
ADU paper entry detection
APOD
ADU paper exit detection
APPD1
ADU paper detection 1
APPD2
ADU paper detection 2
10
10-1
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of the toner motor
and the related circuit.
and the related circuit.
Section
Process (Developing)
Item
Operation
1
Toner motor rotation start
2
Cancel (The display returns to the main code entry menu.)
Press [START] key.
Press [CUSTOM SETTINGS] key to
stop the operations. Or after 10sec.
stop the operations. Or after 10sec.
SIMULATION 9-2
ADU SENSOR CHECK.
ADUSET
DSW_D
AINPD APOD APPD1 APPD2
SIMULATION 10-1
TONER MOTOR ACTIVATION.
ARE YOU SURE?
1.YES
2.NO
2
SIMULATION 10-1
TONER MOTOR ACTIVATION. EXECUTING···.
1
Click on the first or last page to see other AR-M351U / AR-M451U (serv.man17) service manuals if exist.