AR-M316 (serv.man10). ARM256 316 Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 99

Read Sharp AR-M316 (serv.man10) Service Manual online

AR-M256/M257/M258/M316/M317/M318/5625/5631  SIMULATION 8 - 57
* Execution of the simulation which performs communication with the
PCL board is inhibited until Notice Page storage is completed. (Only
when the serviceman call error occurs.)
* In the other case than the serviceman call error, entering the simula-
tion is inhibited during the system check operation is displayed.
Note: Executable only when the PCL is installed.
Operation/procedure
The network scanner is checked.
1.
Press the [START] key.
“PLEASE SEND DATA” and “READY” are displayed. (When the
PCL board is installed, it takes some time to display “READY.”)
2.
Boot “ftp” from MS-DOS.
Data are sent from the PC by the put file name.
The process is displayed. Check the display.
After completion, the result is displayed. 
When the simulation is completed normally, “COMPLETE” is displayed.
(No display for abnormal completion.)
Pressing [CA] key cancels the simulation resets the operation.
* Execution of the simulation which performs communication with the
PCL board is inhibited until Notice Page storage is completed. (Only
when the serviceman call error occurs.)
* In the other case than the serviceman call error, entering the simula-
tion is inhibited during the system check operation is displayed.
Note: Executable only when PCL and NIC are installed.
67-20
Function 
(Purpose)
Used to check the network connection when the 
scanner option is installed.
(TEST DATA)
TEST DATA
(Process status)
RECEIVE
TESTING
Page of 127
Display

Click on the first or last page to see other AR-M316 (serv.man10) service manuals if exist.