AR-M316 (serv.man10). ARM256 316 Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 101

Read Sharp AR-M316 (serv.man10) Service Manual online

AR-M256/M257/M258/M316/M317/M318/5625/5631  TROUBLE CODE LIST 9 - 2
2. Self diagnostics
L4
01
Main motor trouble
11
Shifter motor trouble
L6
10
Polygon motor trouble
L8
10
Power abnormality detection trouble
U1
01
FAX battery error
02
PANEL LOW battery error
U2
04
EEPROM communication error
20
Machine speed code data error
40
CRUM chip communication error
U7
00
RIC communication trouble
U9
00
Operation control PWB communication 
trouble
OPE
80
Operation control PWB communication 
trouble (Protocol)
81
Operation control PWB communication 
trouble (Parity)
82
Operation control PWB communication 
trouble (Overrun)
84
Operation control PWB communication 
trouble (Framing)
88
Operation control PWB communication 
trouble (Time-out)
99
Operation panel destination error
EE
EL
Developer adjustment trouble 
(Over-toned abnormality)
EU
Developer adjustment trouble 
(Under-toned abnormality)
PF
00
PF trouble
Trouble 
code
Details of trouble
Main 
code
Sub 
code
A0
01
Content
Security incompatibility error
Details
When the PCL or the FAX control PWB is 
installed, it does not match with 
compatible/incompatible setup of the MCU 
PWB security.
Cause
The security compatibility/incompatibility of 
the installed PCL or FAX control PWB 
does not match with that of the MCU PWB. 
Check 
and 
remedy
Cheek the security compatibility/
incompatibility of each board. Match the 
security compatibility/incompatibility of the 
boards. 
E1
00
Content
IMC PWB communication trouble
Details
Communication trouble between MCU and 
IMC PWB
Cause
IMC PWB connector disconnection.
Motherboard connector pin breakage.
IMC PWB ROM defect, data failure.
Check 
and 
remedy
Check the connectors of the IMC PWB and 
MCU PWB.
Check the grounding of the copier.
Check the ROM of the IMC PWB.
10
Content
IMC PWB trouble
Details
IMC PWB hardware abnormality
Cause
IMC PWB abnormality
Check 
and 
remedy
Replace the IMC PWB
Trouble code
Trouble contents
Trouble 
detection
Main 
code
Sub 
code
E1
11
Content
IMC PWB ASIC error
Details
ASIC abnormality on IMC PWB
Cause
IMC PWB abnormality
Check 
and 
remedy
Replace the IMC PWB
12
Content
IMC PWB CODEC IC error
Details
CODEC IC (JBIG chip) abnormality on 
IMC PWB
Cause
IMC PWB abnormality
Check 
and 
remedy
Replace the IMC PWB
13
Content
IMC PWB flash ROM error
Details
Flash ROM abnormality on IMC PWB
Cause
IMC PWB abnormality
Check 
and 
remedy
Replace the IMC PWB.
When the program download is abnormally 
terminated, a error may occur. In this case, 
download the program again.
Remarks
Program ROM abnormality
14
Content
IMC PWB expanded memory module 
(DIMM) error
Details
IMC extended compression memory 
module (DIMM) installation error.
IMC extended compression memory 
module (DIMM) access error.
Cause
IMC expanded memory module installation 
trouble.
IMC expanded memory module trouble.
IMC expanded memory contact trouble.
IMC PWB abnormality.
Check 
and 
remedy
Check installation of the expanded 
memory module. (Spec: Added to Slot 1.)
Replace the expanded memory module.
Replace the IMC PWB.
Remarks
Extend memory abnormality for 
compressed image store (DIMM module)
15
Content
IMC PWB page memory error
/SRAM error
Details
IMC PWB page memory or work SRAM 
access error
Cause
IMC PWB abnormality
Check 
and 
remedy
Replace the IMC PWB
Remarks
Print buffer page memory or work SRAM 
abnormality
16
Content
IMC PWB standard compression  memory 
error
Details
Access error of  standard compression 
memory  on IMC PWB
Cause
IMC PWB abnormality
Check 
and 
remedy
Replace the IMC PWB
Remarks
Standard compression image store 
memory abnormality
17
Content
IMC PWB smoothing IC error
Details
IMC PWB smoothing IC abnormality
Cause
IMC PWB abnormality
Check 
and 
remedy
Replace the IMC PWB
Trouble 
code
Details of trouble
Main 
code
Sub 
code
Page of 127
Display