Read Sharp AR-C330 (serv.man5) Service Manual online
AR-C330 SIMULATION 8 - 5
24
8
Used to clear the waste toner counter
in the transfer section.
in the transfer section.
Data clear
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
(Photoconductor/
Developing/Transfer/
Cleaning)
Copy
Counter
9
Printer/Other counter clear
Data clear
Printer
Counter
25
1
Used to check the operation of the main
drive (excluding the scanner section) and
the toner density sensor. (The toner
density sensor output can be monitored.)
drive (excluding the scanner section) and
the toner density sensor. (The toner
density sensor output can be monitored.)
Operation test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
(Photoconductor/
Developing/Transfer/
Cleaning)
Developer/
Toner Hopper
Toner Hopper
Operation
2
Used to make the initial setup
(automatic adjustment) of toner density
when replacing developer.
(automatic adjustment) of toner density
when replacing developer.
Setting
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
(Photoconductor/
Developing/Transfer/
Cleaning)
Developer/
Toner Hopper
Toner Hopper
26
1
Used to make option setup. (When
installing an option,this simulation is
used to setup for that option (software).
installing an option,this simulation is
used to setup for that option (software).
Setting
Specifications
Options
2
1) Used to set the paper size of the
large capacity tray. (When the
paper size is changed, the software
setup must be changed
accordingly with this simulation.)
paper size is changed, the software
setup must be changed
accordingly with this simulation.)
2) Used to detect 8.5 x 13 (INCH
Series) paper or documents and to
set the display mode. (All paper
feed modes)
set the display mode. (All paper
feed modes)
3) Used to set the display form of the
paper kind in the manual paper
feed mode.
feed mode.
Setting
Paper transport
Specifications
3
Used to set the auditor specification
mode. Setting must be made according
to the use conditions of the auditor.
mode. Setting must be made according
to the use conditions of the auditor.
Setting
Auditor
Specifications
5
Used to set the count mode of the total
counter, the developer counter, and the
maintenance counter.
counter, the developer counter, and the
maintenance counter.
Setting
Specifications
Counter
6
1) Used to set the specifications
(paper, fixed copy magnification
ratio, machine operations in case
of an image (process) correction
error) according to the destination.
ratio, machine operations in case
of an image (process) correction
error) according to the destination.
Setting
Specifications
Destination
18
Used to set YES/NO of toner save
operation. (This simulation is valid only for
Japan and UK versions. It depends on Sim
26-6 (Destination) setting. For the other
destinations, the same setting can be
made by the user program P22. (Effective
only in the monochrome copy mode)
operation. (This simulation is valid only for
Japan and UK versions. It depends on Sim
26-6 (Destination) setting. For the other
destinations, the same setting can be
made by the user program P22. (Effective
only in the monochrome copy mode)
Setting
Specifications Operation mode
(Common)
22
Used to set the specification
(language) for the destination.
(language) for the destination.
Setting
Specifications
Language
28
Used to set the AC power voltage. (For
control of the fusing section heater lamp)
control of the fusing section heater lamp)
Setting
Power supply (DC/AC/
High)
High)
Operation
30
Used to set the CE mark complying
operation mode. (Conforms to the soft
start when driving the fusing heater lamp.)
operation mode. (Conforms to the soft
start when driving the fusing heater lamp.)
Setting
Fixing (Fusing)
Specifications
Operation mode
(Common)
(Common)
32
Used to set the fan rotating speed. (low
speed)
speed)
Setting
Operation
35
Used to set whether the trouble history
display by SIM 22-4 is displayed as one
trouble or as the accumulated number of
continuous troubles when two or more
troubles of same kind occur continuously.
display by SIM 22-4 is displayed as one
trouble or as the accumulated number of
continuous troubles when two or more
troubles of same kind occur continuously.
Setting
Specifications
52
Used to set YES/NO of count up of non-
copy paper (cover or insertion paper).
copy paper (cover or insertion paper).
Setting
Specification
Operation mode
53
Used by the user to set Enable/Disable
auto color calibration (auto adjustment
of color balance and density)
auto color calibration (auto adjustment
of color balance and density)
Setting
Specifications
Operation mode
55
Used to select the gamma
characteristics in the color copy mode.
characteristics in the color copy mode.
Setting
ICU
Operation
56
Used to set Disable/Enable of paper
type setting of key operation P67 and
P68.
type setting of key operation P67 and
P68.
Setting
Code
Function (Purpose)
Purpose
Section
Item
Main