AR-C330  SETTING AND ADJUSTMENTS  7 - 39
This adjustment is used to adjust color balance and the density
according to the user's demand.
The adjustment is made by setting the max. density level of Y, M
and C in each color.
This adjustment is required in the following cases when the default
was changed:
• When a consumable part (developer, photoconductor drum,
transfer belt) is replaced.
• When the CCD unit is replaced.
• When the scanner (reading) section is cleaned.
• When U2 trouble occurs.
• When the ICU MAIN PWB is replaced.
• When the EEPROM of the ICU MAIN PWB is replaced.
a. Note for the adjustment
• This adjustment is not required in the normal state, but executed
only when the user requests for.
b. Adjustment procedure
1) Enter the SIM 46-25 mode.
2) Select the color to be adjusted with the scroll key.
3) Select the color with the color key.
4) Enter the adjustment value of each toner color with the 10-key.
(Default)
5) Cancel the simulation mode and make a copy in the single
color copy mode to check.
A. Outline
This setup is used to set the priority order between brightness and
gradation in the color copy mode. The setup affects the gamma
characteristic in the high-density area.
1) Enter the SIM 26-55 mode.
2) Press ENABLE or DISABLE key.
A. Outline
The user can perform the copy color balance and auto density
adjustment in the user program mode.
SIIM 26-53 is used to Enable or Disable this operation.
NOTE: This setup is performed only when the user understands
the copy color balance and the auto density adjustment
and is capable of performing the operation.
Full explanations on the operating procedure, notes, and
operations must be given to the user.
• When a U2 trouble occurs.
• When the PCU main PWB is replaced.
• When the EEPROM on the PCU main PWB is replaced.
B. Setup procedure
1) Enter the SIM 26-53 mode.
2) Select Enable/Disable with the 10-key.
Disabling = 0: YES
Enabling = 1: NO
3) Press the OK key.
When "0: YES" (Disabling) is selected, the user auto color calibra-
tion (copy color balance, auto density adjustment) menu is not dis-
played in the user program mode.
This adjustment must be performed in the following cases:
• When the original size sensor section is disassembled.
• When the original size sensor section is replaced.
• When a U2 trouble occurs.
• When the PCU main PWB is replaced.
• When the EEPROM of the PCU main PWB is replaced.
1) Enter the SIM 41-1 mode.
Gradually tilt the original detection arm unit. Loosen the origi-
nal cover switch actuator adjustment screw so that the high-
light display of OCSW is turned to the normal display when the
height of the arm unit top from the table glass is 32 ± 0.5mm.
Slide the actuator to adjust. (If the ON timing of the original
cover switch is shifted, the original detection function may mal-
function.)
ADJ 7
Single color copy mode color 
balance and density adjustment 
(Normally unnecessary to adjust.)
Default
C
M
Y
RED
0
255
255
GREEN
255
0
255
BLUE
255
255
0
PURPLE
148
238
105
ORANGE
38
140
255
BROWN
131
255
229
ADJ 8
Setup of the gamma characteristic in 
the color copy mode
ENABLE:
The contrast in the high-density area is increasing,
and the gradation is slightly decreased. (Priority is
given to brightness.)
DISABLE:
Normal picture quality (Priority is given to gradation.)
ADJ 9
User auto color calibration (Copy 
color balance, auto density 
adjustment) enable setup
ADJ M18
Document size sensor adjustment
ADJ 1
Original size sensor detection point 
adjustment