AR-C270 (serv.man6). (Section 5) External View Internal Structure - Sharp Copying Equipment Service Manual (repair manual). Page 9

Read Sharp AR-C270 (serv.man6) Service Manual online

No.
Parts
Note
Code
Name
Type
Spec
Function/Operation
12
F704
DC main power
+ 24V
Normal fuse
125V 6.3A
Protects the PCU main PWB from an
overcurrent.
100V series
DC main power
+ 24V
Normal fuse
250V 6.3A
Protects the PCU main PWB and the high
voltage PWB (MC/DN) from an overcurrent.
200V series
13
F705
DC main power
+ 24V
Normal fuse
125V 6.3A
Protects the PCU main PWB and the high
voltage PWB (MC/DN) from an overcurrent.
100V series
DC main power
+ 24V
Normal fuse
250V 6.3A
Protects the PCU main PWB from an
overcurrent.
200V series
14
F706
DC main power
+ 24V
Normal fuse
125V 6.3A
Protects the scanner motor control PWB, LSU,
and CCD power PWB from an overcurrent.
100V series
DC main power
+ 24V
Normal fuse
250V 6.3A
Protects the scanner motor control PWB, LSU,
and CCD power PWB from an overcurrent.
200V series
15
F707
DC main power
+ 24V
Normal fuse
125V 6.3A
Protects the process control PWB, the OPC
drum control PWB, and the developing motor
(color) from an overcurrent.
100V series
DC main power
+ 24V
Normal fuse
250V 6.3A
Protects the process control PWB, the OPC
drum control PWB, and the developing motor
(color) from an overcurrent.
200V series
16
F708
DC main power
+ 24V
Normal fuse
125V 6.3A
Protects the PCU main PWB, RADF, the sorter,
the large capacity paper tray, the OPC drum
control PWB, and the developing motor (color)
from an overcurrent.
100V series
DC main power
+ 24V
Normal fuse
250V 6.3A
Protects the PCU main PWB, RADF, the sorter,
the large capacity paper tray, the OPC drum
control PWB, and the developing motor (color)
from an overcurrent.
200V series
17
Scanner lamp
temperature fuse
Temperature
fuse
104° C 250V
10A
Cuts conduction to the scanner lamp when the
temperature rises abnormally.
(AR-C160/C270)
1
2
3
5
6
7
100V
200V
9
10
11
8
9
10
11
12
5 –  11A
Page of 12
Display