AR-C270 (serv.man6). (Section 5) External View Internal Structure - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp AR-C270 (serv.man6) Service Manual online

(AR-C160/C270)
No.
Parts
Note
Name
Function/Operation
Spec
1
CCD power PWB
Outputs the CCD PWB power.
2
High voltage power
PWB (TC)
Generates the transfer voltage.
3
Fusing control PWB
(AC sub PWB)
Interfaces the heater lamp drive control, the sensor, and the
detector signals.
4
DC main power PWB
Generates a voltage used by the other unit than the operation unit.
5
Dc sub power PWB
(AR-C150/C250)
Power control PWB
(AR-C160/C270)
Generates a voltage for the operation unit (AR-C150/C250)
Controls powers of 24V, 5V and 3.3V in the sleep mode, the
preheat mode, and the normal mode. (AR-C160/C270)
6
AC main power PWB
Controls the power (AC power) on the primary side.
7
High voltage power PB
(MC/DV)
Generates the high voltage for the main charger and the developing
bias voltage.
(11) Adjustment volumes
(AR-C150/C250)
1
2
3
4
6
5
7
2
3
4
1
5 –  13A
Page of 12
Display