AR-C270 (serv.man6). (Section 5) External View Internal Structure - Sharp Copying Equipment Service Manual (repair manual). Page 8

Read Sharp AR-C270 (serv.man6) Service Manual online

(9) Fuses, thermostat
(AR-C150/C250)
No.
Parts
Note
Code
Name
Type
Spec
Function/Operation
1
F1
Scanner motor
power fuse
Normal fuse
Protects the scanner motor and its control
circuit from an overcurrent.
Scanner motor
control PWB
2
HLTSU
Upper heat roller
thermostat
Thermostat
Cuts conduction to the heater lamp when the
temperature rises abnormally.
Fusing unit
3
HLTSD
Lower heat roller
thermostat
Thermostat
Cuts conduction to the heater lamp when the
temperature rises abnormally.
Fusing unit
4
F101
OPC drum motor
power fuse
Normal fuse
Protects the OPC drum motor and its control
circuit from an overcurrent.
OPC drum motor
control PWB
5
F701
Scanner lamp
power fuse
Normal fuse
250V 4A
Protects the scanner lamp from an overcurrent.
Scanner lamp
control PWB
6
F712
DC sub power
26V power fuse
Normal fuse
250V 1A
Protects the PCC main PWB and the operation
control PWB form an overcurrent.
DC sub power
PWB
7
F711
DC sub power
primary size fuse
Normal fuse
250V 3.15A
Protects the DC sub power primary side from
an overcurrent.
DC sub power
PWB
8
F101
AC main power
primary side fuse
Normal fuse
125V 20A
Protect the AC main power primary side from
an overcurrent.
Japan
AC main power
primary side fuse
Normal fuse
250V 15A
Protect the AC main power primary side from
an overcurrent.
100V series
AC main power
primary side fuse
Normal fuse
240V 10A
Protect the AC main power primary side from
an overcurrent.
200V series
9
F102
AC main power
primary side fuse
Normal fuse
125V 20A
Protect the AC main power primary side from
an overcurrent.
Japan
AC main power
primary side fuse
Normal fuse
240V 10A
Protect the AC main power primary side from
an overcurrent.
200V series
10
F702
DC main power
+ 5V fuse
Normal fuse
125V 6.3A
Protects the ICU PWB from an overcurrent.
100V series
11
F703
DC main power
+ 5V fuse
Normal fuse
125V 6.3A
Protects the PCU main PWB, LSU, and CCD
power PWB from an overcurrent.
100V series
1
2
10
16
3
17
4
5
6
7
8
9
11
12
13
14
15
5 –  10A
Page of 12