AR-C260 (serv.man10). All Sections - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp AR-C260 (serv.man10) Service Manual online

AR-C260/C260M  DESCRIPTIONS OF EACH SECTION  7 - 11
(2) Maintenance parts replacement procedure
a. Transfer unit removal
1) Open the left cabinet, and remove the fusing unit. (Refer to the
section of the fusing unit.) 
2) Hold section A of the transfer unit and pull it in the arrow direction
so that you can hold both sides of the unit. 
3) Hold both sides B and remove the transfer unit from the machine.
Note: Be careful not to scratch the surface of the transfer belt.
b. Belt drive motor
1) Remove the transfer unit from the machine.
2) Remove the screw, and remove the belt cover gear.
3) Remove the connector, the screw, and the motor.
c. Process control sensor
1) Remove the transfer unit from the machine. 
2) Remove the connector and the screw, and remove the belt drive
unit.
3) Remove the spring from the hook section.
4) Remove the hook, and remove the process control shutter.
Cleaning: Clean the calibration sheet. (Wipe with soft, dry cloth.)
A
B
A
A
B
B
Page of 46
Display