AR-235 (serv.man9). Adjustments, setting Simulation Trouble code list - Sharp Copying Equipment Service Manual (repair manual). Page 48

Read Sharp AR-235 (serv.man9) Service Manual online

AR-235/275 SIMULATION - 39
1) After  checking  the  data  in  the  management  information,  reading
from  the  expanded  memory  and  writing  into  the  SRAM  are  per-
formed.
2) After completion of writing into the SRAM, the expanded memory
is initialized for normal use again.
3) After  completion  of  initializing  the  expanded  memory,  the  SRAM
RESTORE operation of the simulation is terminated. 
1) Before  saving,  install  the  expanded  memory  to  be  used.  (During
power OFF)
2) In the SRAM backup menu (66-53), SRAM BACK UP is selected,
and the process to save SRAM data into the expanded memory is
executed.
3) After completion of saving, turn off the power.
1) Install the expanded memory into which data are written according
to the above procedures. (During power OFF)
2) In the SRAM backup menu (66-53), SRAM RESTORE is selected
to write the SRAM data which was saved into the expanded mem-
ory into the SRAM of the FAX board.
Note: Executable only when the FAX is installed.
Operation/procedure (Pattern 1)
Enter the adjustment value with the 10-key and press the [OK] key, and
the entered value is registered.
Note: Executable only when the PCL is installed.
Operation/procedure
Download PCL.
Pressing  the  [OK]  key  displays  "Please  Send  Data"  "Ready"  and  the
data is sent from the PC under the MS-DOS command of FCOPY and
the file name.
Used to overwrite and check the flash device while displaying its pro-
cess status.
After completion, the result is displayed.
(It takes a little time to display READY.) 
Press the [CA] key to cancel the simulation and reset.
Note: Executable only when the PCL is installed.
Operation/procedure (Pattern 7)
Pressing the [OK] key displays the confirmation message.
Press  the  [OK]  key  again  to  clear.  Press  the  [BACK]  key  to  interrupt
clearing.
If  there  is  no  abnormality  after  Clear  operation,  "COMPLETE"  is  dis-
played. If there is any abnormality, "ERROR" is displayed. 
Note: Executable only when the PCL is installed.
Operation/procedure (Pattern 7)
Pressing the [OK] key displays the confirmation message.
Press  the  [OK]  key  again  to  clear.  Press  the  [BACK]  key  to  interrupt
clearing.
If  there  is  no  abnormality  after  Clear  operation,  "COMPLETE"  is  dis-
played. If there is any abnormality, "ERROR" is displayed. 
Note: Executable only when the PCL is installed.
Process when reading the expanded memory
Remark 1: SRAM data saving procedure
Remark 2: SRAM data reading procedure
67
67-11
Purpose
Setting
Function (Purpose)
Used to set the Select-IN signal.
Setting range
0-1
Default
0
67-14
Function (Purpose)
Used to check write/comparison of flash 
programs.
Sim67-11 SELECT-IN
SELECT-IN SIGNAL  0
  (0:ON 1:OFF)
     [  0-  1]    
0
(Normal end screen)
(Abnormal end screen)
(Flash Device)
PROGRAM
BOOTROM
PS KANJI FONT
ESC/P KANJI FONT
OPTION FONT
(Processing state)
RECEIVE
ERASE
WRITE
VERIFY
67-17
Function (Purpose)
Used to clear NVRAM.
(Initial screen)
(Process check screen)
(Executing screen)
(Normal end screen)
(Abnormal end screen)
67-18
Function (Purpose)
Used to clear the data area for FLASH ROM 
Network Scanner Application.
(Initial screen)
(Process check screen)
(Executing screen)
(Normal end screen)
(Abnormal end screen)
Sim67-14 FLASH D/L
PRESS OK KEY
Sim67-14 FLASH D/L
Please Send Data
READY
Sim67-14 FLASH D/L
PROGRAM
RECEIVE
Sim67-14 FLASH D/L
COMPLETE
Sim67-14 FLASH D/L
FAILED
Sim67-17 NVRAM CLR.
NVRAM CLEAR
PRESS OK KEY
Sim67-17 NVRAM CLR.
NVRAM CLEAR
ARE YOU SURE?
Sim67-17 NVRAM CLR.
NVRAM CLEAR
NOW DOING...
Sim67-17 NVRAM CLR.
NVRAM CLEAR
COMPLETE
PRESS OK KEY
Sim67-17 NVRAM CLR.
NVRAM CLEAR
ERROR
PRESS OK KEY
Sim67-18 APP. CLR.
APP. DATA CLEAR
PRESS OK KEY
Sim67-18 APP. CLR.
APP. DATA CLEAR
ARE YOU SURE?
Sim67-18 APP. CLR.
APP. DATA CLEAR
NOW DOING...
Sim67-18 APP. CLR.
APP. DATA CLEAR
COMPLETE
PRESS OK KEY
Sim67-18 APP. CLR.
APP. DATA CLEAR
ERROR
PRESS OK KEY