Read Sharp AR-235 (serv.man9) Service Manual online
AR-235/275 SIMULATION - 39
1) After checking the data in the management information, reading
from the expanded memory and writing into the SRAM are per-
formed.
formed.
2) After completion of writing into the SRAM, the expanded memory
is initialized for normal use again.
3) After completion of initializing the expanded memory, the SRAM
RESTORE operation of the simulation is terminated.
1) Before saving, install the expanded memory to be used. (During
power OFF)
2) In the SRAM backup menu (66-53), SRAM BACK UP is selected,
and the process to save SRAM data into the expanded memory is
executed.
executed.
3) After completion of saving, turn off the power.
1) Install the expanded memory into which data are written according
to the above procedures. (During power OFF)
2) In the SRAM backup menu (66-53), SRAM RESTORE is selected
to write the SRAM data which was saved into the expanded mem-
ory into the SRAM of the FAX board.
ory into the SRAM of the FAX board.
Note: Executable only when the FAX is installed.
Operation/procedure (Pattern 1)
Enter the adjustment value with the 10-key and press the [OK] key, and
the entered value is registered.
the entered value is registered.
Note: Executable only when the PCL is installed.
Operation/procedure
Download PCL.
Pressing the [OK] key displays "Please Send Data" "Ready" and the
data is sent from the PC under the MS-DOS command of FCOPY and
the file name.
data is sent from the PC under the MS-DOS command of FCOPY and
the file name.
Used to overwrite and check the flash device while displaying its pro-
cess status.
cess status.
After completion, the result is displayed.
(It takes a little time to display READY.)
Press the [CA] key to cancel the simulation and reset.
Note: Executable only when the PCL is installed.
Operation/procedure (Pattern 7)
Pressing the [OK] key displays the confirmation message.
Press the [OK] key again to clear. Press the [BACK] key to interrupt
clearing.
clearing.
If there is no abnormality after Clear operation, "COMPLETE" is dis-
played. If there is any abnormality, "ERROR" is displayed.
played. If there is any abnormality, "ERROR" is displayed.
Note: Executable only when the PCL is installed.
Operation/procedure (Pattern 7)
Pressing the [OK] key displays the confirmation message.
Press the [OK] key again to clear. Press the [BACK] key to interrupt
clearing.
clearing.
If there is no abnormality after Clear operation, "COMPLETE" is dis-
played. If there is any abnormality, "ERROR" is displayed.
played. If there is any abnormality, "ERROR" is displayed.
Note: Executable only when the PCL is installed.
Process when reading the expanded memory
Remark 1: SRAM data saving procedure
Remark 2: SRAM data reading procedure
67
67-11
Purpose
Setting
Function (Purpose)
Used to set the Select-IN signal.
Setting range
0-1
Default
0
67-14
Function (Purpose)
Used to check write/comparison of flash
programs.
programs.
Sim67-11 SELECT-IN
SELECT-IN SIGNAL 0
(0:ON 1:OFF)
[ 0- 1]
0
(Normal end screen)
(Abnormal end screen)
(Flash Device)
PROGRAM
BOOTROM
PS KANJI FONT
ESC/P KANJI FONT
OPTION FONT
PROGRAM
BOOTROM
PS KANJI FONT
ESC/P KANJI FONT
OPTION FONT
(Processing state)
RECEIVE
ERASE
WRITE
VERIFY
RECEIVE
ERASE
WRITE
VERIFY
67-17
Function (Purpose)
Used to clear NVRAM.
(Initial screen)
(Process check screen)
(Executing screen)
(Normal end screen)
(Abnormal end screen)
67-18
Function (Purpose)
Used to clear the data area for FLASH ROM
Network Scanner Application.
Network Scanner Application.
(Initial screen)
(Process check screen)
(Executing screen)
(Normal end screen)
(Abnormal end screen)
Sim67-14 FLASH D/L
PRESS OK KEY
Sim67-14 FLASH D/L
Please Send Data
READY
Sim67-14 FLASH D/L
PROGRAM
RECEIVE
Sim67-14 FLASH D/L
COMPLETE
Sim67-14 FLASH D/L
FAILED
Sim67-17 NVRAM CLR.
NVRAM CLEAR
PRESS OK KEY
Sim67-17 NVRAM CLR.
NVRAM CLEAR
ARE YOU SURE?
Sim67-17 NVRAM CLR.
NVRAM CLEAR
NOW DOING...
Sim67-17 NVRAM CLR.
NVRAM CLEAR
COMPLETE
PRESS OK KEY
Sim67-17 NVRAM CLR.
NVRAM CLEAR
ERROR
PRESS OK KEY
Sim67-18 APP. CLR.
APP. DATA CLEAR
PRESS OK KEY
Sim67-18 APP. CLR.
APP. DATA CLEAR
ARE YOU SURE?
Sim67-18 APP. CLR.
APP. DATA CLEAR
NOW DOING...
Sim67-18 APP. CLR.
APP. DATA CLEAR
COMPLETE
PRESS OK KEY
Sim67-18 APP. CLR.
APP. DATA CLEAR
ERROR
PRESS OK KEY
Click on the first or last page to see other AR-235 (serv.man9) service manuals if exist.