AR-205 (serv.man10). AR205 Service Manual-Simulations - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp AR-205 (serv.man10) Service Manual online

Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
26
51
Sort/Group copy
temporary stop function
setup
<Only when an option
is installed>
Used to set whether temporary stop for every 250-sheet print (150-sheet
print when the job separator is installed) is made or not during copying
with the sort/group function. The current setup is displayed with the
following numbers. After entering the set value, press the start key to
store the set value.
1
0.1
30
1
Machine sensor operation
check
Used to check the sensors in the machine transport system with LED on
the operation panel.
41
2
OC document sensor
adjustment
<Other than AR-160>
Used to read the document sensor input value with paper and perform
the sensor detection level adjustment. For the adjustment procedure of
the document sensor input value, refer to the previous descriptions.
41
3
Document sensor light
reception level display
<Other than AR-160>
Used to display the light reception level and the detection level of the
document sensor. (The sensor level adjusted with SIM 41-2 is displayed.)
42
1
Developing counter clear
Used to clear the Developing counter. 
2
43
1
Fusing temperature setting
Used to display the current setting of the fusing temperature at right.
After selecting the fusing temperature with the magnification ratio display
key, press the start key, and the set value is stored. The set range is
155 
 190˚C. Use the magnification ratio key to adjust the value by –5˚C.
180
155 
 190
46
1
Copy density level
adjustment
After completion of warmup, shading is performed and the currently set
copy density level is displayed. For the adjustment procedure, refer to
the previous descriptions.
48
 99
2: Display after clearing each counter 
000 (0.75 sec) 
 Blank (0.35 sec) 
 000 (0.75 sec) 
 Blank (1.0 sec) 
 Repetition
Key operation/Display
0: Does not stop.
1: Stops.
Display
<Lighting at sensor ON>
Paper entry sensor: Machine position JAM LED
Duplex sensor: SPF JAM LED <Only AR-205>
Paper exit sensor: JAM LED
No. 2 cassette transport sensor: No. 2 cassette position LED
No. 3 cassette transport sensor: No. 3 cassette position LED
<Only when an option is installed>
No. 4 cassette transport sensor: No. 4 cassette position LED
<Only when an option is installed>
Drum initial SW: DRUM LED
Key operation
Display
Light reception/Detection
level select: Magnification
ratio display key
Display at the 3rd digit
“A”:
Light reception level display
“b”:
Document detection level display
Sensor select: Auto
magnification ratio select key
Sensor A: A3 (11 
×
 17) document
size LED
Sensor B: A4 (8 1/2 
×
 14) document
size LED
Sensor C: A4R (8 1/2 
×
 11)
document size LED
Sensor D: B4 (8 1/2 
×
 5 1/2)
document size LED
Key operation
Fusing temperature select: Magnification ratio display key
Key operation
Display
Mode select:
Exposure mode select
key
Copy density level:
Copy quantity keys
<LED lighting at each mode selection>
Auto mode: AUTO LED
Manual mode: MANUAL LED
Photo mode: PHOTO LED
Toner save mode: MANUAL + PHOTO LED
AETS mode: AUTO + PHOTO LED
AR-205
7 – 9
Page of 14
Display

Click on the first or last page to see other AR-205 (serv.man10) service manuals if exist.