Read Sharp AL-840 (serv.man6) Service Manual online
*
Work content
1) Set the test chart with three sheets of A4 (11
×
8.5) paper on the
document table as shown below and close the document cover.
2) Set the copy density level of the manual copy mode and the photo
copy mode to the center.
(Select the photo mode with the copy mode key and press and
hold the key for 5 sec or more, and the auto copy mode display
lamp will blink. Under this state, use the copy density adjustment
key to set the copy density level to the center. When the copy
mode key is pressed after this, the adjusted level is set and the
copy mode display lamp will change from blinking to lighting and
the machine will return to the normal mode.)
(Select the photo mode with the copy mode key and press and
hold the key for 5 sec or more, and the auto copy mode display
lamp will blink. Under this state, use the copy density adjustment
key to set the copy density level to the center. When the copy
mode key is pressed after this, the adjusted level is set and the
copy mode display lamp will change from blinking to lighting and
the machine will return to the normal mode.)
3) Enter the test command (simulation) 46-1 mode.
4) Select the copy mode to be adjusted with the copy picture quality
mode select key.
(The currently set copy density adjustment level is displayed on
the copy quantity display.)
(The currently set copy density adjustment level is displayed on
the copy quantity display.)
5) Change and adjust the set value so that the following copy density
copy is made.
To change the copy density, change the adjustment value and press
the start button.
the start button.
(The adjustment value is stored and a copy is made)
To decrease the copy density, decrease the adjustment value. To
increase the copy density, increase the adjustment value. When the
exposure level of the center density level is adjusted, the copy density
in the other density level is automatically calculated and adjusted.
increase the copy density, increase the adjustment value. When the
exposure level of the center density level is adjusted, the copy density
in the other density level is automatically calculated and adjusted.
The adjustment value can be set in the range of 0
∼
99.
Perform procedures 4)
∼
6) for each copy mode.
(Test chart comparison table)
UKOG-0162FCZZ
DENSITY No
DENSITY No
1
2
3
4
5
6
7
8
9
10
W
UKOG-0089CSZZ
DENSITY No
DENSITY No
0.1
0.2
0.3
0.5
1.9
0
KODAK GRAY
SCALE
SCALE
1
2
3
4
19
A
*
Preliminary work
JOB No
Content
S 004
Scanner (reading) section cleaning
S 006
Image process section cleaning
S 007
Fusing section cleaning
*
Necessary tools
One of the following test charts is required.
Name
Gray scale chart
Parts code/Price rank
UKOG-0162FCZZ
Name
SHARP original test chart
Parts code/Price rank
UKOG-0089FCZZ
Name
KODAK gray scale chart
Parts code/Price rank
Commercially available
ADJ M2
Copy image distortion adjustment
Content
Preliminary
work
After-
work
JOB No
JOB No
ADJ M2
Copy distortion
adjustment
adjustment
ADJ 1 Scanner unit
parallelism
adjustment
(Mechanical
adjustment)
adjustment
(Mechanical
adjustment)
ADJ M2/
ADJ 2
ADJ 2
ADJ 2 Copy sub
scanning direction
distortion
adjustment
distortion
adjustment
ADJ M2/
ADJ 1
ADJ 1
ADJ M2/
ADJ 3
ADJ 3
ADJ 3 Copy main
scanning direction
distortion
adjustment
distortion
adjustment
ADJ M2/
ADJ 2
ADJ 2
ADJ M3
ADJ 1
Scanner unit parallelism adjustment
*
Location
*
Execution condition (time)
Enforcement
time
time
JOB No
Content
S 004
When any part in the scanner
(reading) section is
disassembled or replaced.
(reading) section is
disassembled or replaced.
Cycle
—
Condition
When the copy image
distortion is outside the
allowable range.
distortion is outside the
allowable range.
A6
B6
51/2
A5
B5
81/2
A4
A4(11x8.5")
White paper
White paper
Test chart
1 3 5
AUTO
ONLINE
PREHEAT
MANUAL
PHOTO
1
10
W
2
3
4
5
6
7
8
9
SHARP gray scale adjustment level
Copied
Not copied
1
10
W
2
3
4
5
6
7
8
9
7 – 3