PN-ZB01 (serv.man2) - Sharp Monitor Service Manual (repair manual). Page 12

Read Sharp PN-ZB01 (serv.man2) Service Manual online

CHAPTER 1. OUTLINE OF THE PRODUCT
PN-E601 OUTLINE OF THE PRODUCT
 1 – 8
2. PART NAMES AND FUNCTION
2 - 1. DISPLAY
■ FRONT VIEW
*
Use a pointed object such as a pen tip to press the switches at the front of the monitor.
REFERENCE CHART OF POWER LAMP LIGHTING STATUS
1
5
4
3
2
1 LCD panel
2 Remote control sensor
3 INPUT switch
4 POWER switch
5 Power LED
Lighting Status
Status Description
Green lamp is lit.
In the power “ON” state
Green lamp is flashing.
In the input signal waiting mode
Orange lamp is lit.
In the power “OFF” state (Standby status=The power is turned off by the remote controller.)
If the Power switch is pressed when the display is in the input signal waiting mode (green lamp flashing), it also goes 
into the standby status.
Orange lamp is flashing.
When the Power On Delay function is activated, the power lamp blinks in orange (at about 1 second intervals).
If the setting is set to “0” (factory default), the function gets disabled and the lamp won’t blink.
The Power On Delay function enables a time delay from the turning-on of power till the display of screen, and the set-
ting can be set in 1 second increments up to 60 seconds.
*
This function is supposed to be set by a user.  However, if it has been set by mistake, this causes the orange
lamp’s flashing.
Lamp is flashing alter-
nately in red and 
orange.
The schedule has been set in the standby mode.
Lamp is flashing in 
red
3green3red3green 
at 1 second intervals.
The message “TEMPERATURE” blinks at 5-second intervals in the corner of the screen (Lower left corner at the fac-
tory default), and it indicates an abnormality in the internal temperature.
*
When the temperature abnormality indication of the function is set to “LED” or “OFF,” the “Monitor Temperature”
is not displayed. (Set to “LED” at the factory default.)
At the same time, the brightness is forcefully reduced by the internal processing of the LCD monitor.
If it is left in the above state and the internal temperature increases further, the monitor shuts off automatically.  (Goes 
into the standby mode.)
By cycling the main power or turning off and on the power by the remote controller,  the screen can be restored to its 
original state temporarily.  However, it goes back to the standby status soon unless the cause of the temperature 
increase is removed.
Red lamp is flashing.
The message “STATUS” is displayed in the corner of the screen (Lower left corner at the factory default). This indi-
cates an abnormality occurring with the hardware. 
Based on the sensor monitoring data, the defective board/ unit needs to be replaced.
*
When the status indication of the special function is set to “LED” or “OFF,” the “STATUS”  is not displayed. (Set to
“disabled” at the factory default.)