LL-171ME (serv.man3). Complete - Sharp Monitor Service Manual (repair manual). Page 13

Read Sharp LL-171ME (serv.man3) Service Manual online

LL-171ME
CONNECTION, ADJUSTMENT, OPERATION, AND FUNCTIONS
2 – 6
4
Check that [CUSTOM MODE: ON] is displayed in the upper right of
the screen, and executes EXCUTE of the menu. 
•  The release method in custom mode
1) Custom mode is changed to OFF in the above-mentioned proce-
dure 
2
.
2) When a set value of a detailed menu is returned to an initial value,
[RESET] is executed by above-mentioned procedure 
3
3) EXECUTE is performed, the normal mode starts.
4) Turn off a monitor main unit
Caution: Even if it performs [all reset], custom mode is not canceled.
When you cancel custom mode, please be sure to operate it in
the above-mentioned procedure.
(Refer <2-6. Returned to an initial value set value>)
2-8. CUSTOM MODE SPECIFICATION
[How to set up the CUSTOM mode]
(1) [
b
] + [
d
]  + [POWER] buttons on the control panel is pushed to
enter CUSTOM MODE.
(2) "CUSTOM MODE" is selected, then it is changed from "OFF" to
"ON". ("OFF" or "ON" is selectable. Preset is "OFF".)
After the power is turned off, CUSTOM mode is started from the
next power on.
*
CUSTOM mode can be canceled by changing from "ON" to "OFF"
on the above procedure (2).
*
It can be set up by the control panel or the remote controller button
operation. Only the following button works on the CUSTOM MODE
(MENU) screen.
<On the body>
<On the remote controller>
*
The setting for CUSTOM mode can NOT be reset by ALL RESET
([MENU] + [OK/BRIGHT MODE] + [POWER]).
*
The setting for CUSTOM mode can be reset by INITIALIZE
([INPUT] + [MENU]  + [VOLUME/BITHGT 
d
] + [POWER]).
*
In case of ADUSTMENT LCOK ON, when "CUSTOM MODE" is
changed from "OFF" to "ON", ADJUSTMENT LOCK is automatically
changed to OFF. And, ADUSTMENT LOCK can't be turned on.  
*
When ADJUSTMENT LOCK is ON, INITIALIZE and ALL RESET
does not work.
(3) [
d
] button is pushed, pushing [
b
] button on the control panel to dis-
play CUSTOM MODE MENU on CUSTOM MODE OSD.
The following items on the table are set up by the control panel or
the remote controller button operation. 
*
The setting in CUSTOM MODE MENU can NOT be reset by ALL
RESET ([MENU] + [OK/BRIGHT MODE] + [POWER]).
*
The setting in CUSTOM MODE MENU can be reset by INITIALIZE
([INPUT] + [MENU]  + [VOLUME/BITHGT 
d
] + [POWER]).
*
Only when "CUSTOM MODE" is ON, contents of a setup of CUS-
TOM MODE MENU become effective. 
[POWER]
POWER OFF
[MENU]
SELECT
[VOLUME/BITHGT 
d
]
[VOLUME/BITHGT 
e
]
ADJUST/EXCUTE
[POWER]
POWER OFF
[
b
] [
c
]
SELECT
[
e
] [
d
]
ADJUST/EXCUTE
No.
SPEC NAME
(OSD MENU INDICATION)
SUMMARY OF SPEC
SPEC CHOICES
OSD ITEM NAME
0
RETURN (RETURN)
It returns to the previous screen. 
(CUSTOM MODE)
No items
1
CONTROL PANEL
BUTTON LOCK
(CONTROL PANEL BUTTON)
An operation by control panel buttons
(except for power switch) is disabled.
(CHANNEL & VOLUME, INPUT, etc)
An operation by control panel
button
- is enabled
- is disabled
ENABLED (
1
 PRESET)
DISABLED
2
OSD DISPLAY LOCK
(OSD DISPLAY)
All OSD display is disabled.
(CHANNEL,VOLUME, etc)
OSD DISPLAY
- is enabled
- is disabled
ENABLED (
1
 PRESET)
DISABLED
3
START MODE DESIGNATION
(START MODE)
The input mode or the channel is
specified when a power is turned on.
(Switching is available after power is
turned on.)
The input mode or the channel
is
- Not specified.
- specified.
NORMAL (
1
 PRESET)
******
 (INPUT MODE or TV
CHANNEL)
4
PC MODE PERMIT
(PC MODE PERMIT)
PC mode is permitted or not.
PC mode
- is permitted.
- is prohibited.
ENABLED (
1
 PRESET)
DISABLED
5
TV MODE PERMIT
(TV MODE PERMIT)
TV mode is permitted or not.
(In) TV mode
-  ALL CHANNEL is permitted.
-  Specific channel is permitted.
(Only one channel that it is
permitted is specified.)
- is prohibited.
ALL (
1
 PRESET)
CH0 ~ CH99
DISABLED
Page of 43
Display

Click on the first or last page to see other LL-171ME (serv.man3) service manuals if exist.