R-890SLM - Sharp Home Appliance Service Manual (repair manual). Page 7

Read Sharp R-890SLM Service Manual online

R-890SLM
[1] OFF CONDITION
Closing the door activates the monitored latch switch and the 
stop switch.
IMPORTANT
When the oven door is closed, the contacts COM-NC of the 
monitor switch must be open. When the microwave oven is 
plugged in a wall outlet (230 - 240V / 50Hz), the line voltage 
is supplied to the noise filter.
Figure O-1 on page 13-1
1.  The control unit is not energized. The display shows nothing 
(Fig. O-1 (a)).
2.  Open the door. The contacts (COM-NC) of the monitored 
latch switch are closed and the control unit is energized.  
Then contacts of relays RY1 and RY5 are closed, and the 
oven lamp will light and the display will show “ENERGY  
SAVE MODE TO CANCEL ENERGY SAVE MODE SET THE  
CLOCK” (Fig. O-1(b)).
3.  Close the door. The contacts (COM-NC) of the monitored 
latch switch are opened and the contacts of relay RY1 are 
opened and the oven lamp will be turned off. The display will 
show “ . 0”. (Fig. O-1(c)).
NOTE: Energy save mode
 
1)  If the oven has not been used for more than 3 min-
utes, the contacts of the relay RY5 will be opened 
and the control unit will be not energized.    
 
Open and close the door, the control unit will resume.
 
2)  If the clock is set, this energy save mode does not work.
[2] MICROWAVE COOKING CONDITION
1.  HIGH COOKING
Press MICRO POWER button. And enter the cooking time by 
rotate ENCODER dial. And start the oven by press START button.
Function sequence
Figure O-2 on page 13-2
CONNECTED COMPONENTS
RELAY
Oven lamp, Turntable motor
RY1
High voltage transformer 
RY2
Fan motor,
RY6
1. The line voltage is supplied to the primary winding of the high 
voltage transformer. The voltage is converted to about 3.3 
volts A.C. output on the filament winding and high voltage of 
approximately 2000 volts A.C. on the secondary winding.
2.  The filament winding voltage (3.3 volts) heats the magnetron 
filament and the high voltage (2000 volts) is sent to the 
voltage doubling circuit, where it is doubled to negative 
voltage of  approximately 4000 volts D.C..
3.  The 2450 MHz microwave energy produced in the magnetron 
generates  a  wavelength  of  12.24cm.  This  energy  is 
channelled through the waveguide (transport channel) into 
the oven cavity, where the food is placed to be cooked.
4.  When the cooking time is up, a signal tone is heard and the 
relays RY1 + RY2 + RY6 go back to their home position. The 
circuits to the oven lamp, high voltage transformer, fan motor 
and turntable motor are cut off.
5.  When the oven door is opened during a cooking cycle, the 
switches come to the following condition.
CHAPTER 5. OPERATION SEQUENCE
 
SWITCH
 
CONTACT
 CONDITION
DURING
COOKING
DOOR OPEN
(NO COOKING)
Monitored latch
switch
COM-NO
COM-NC
Closed 
Opened
Opened
Closed
Stop switch
COM-NO 
Closed 
Opened
Monitor switch
COM-NO
COM-NC 
Closed 
Opened
Opened
Closed
The circuit to the high voltage transformer is cut off when the 
contacts of relay RY2, and the contacts (COM-NO) of the moni-
tored latch switch and monitor switch are made open. The circuit 
to the fan motor is cut off when the relay RY6 is made open. 
The circuit to the turntable motor is cut off when the contacts 
(COM-NO) of the monitored latch switch are made open. The 
relay RY2 and RY6 are made open when the door is opened. 
The oven lamp remains on even if the oven door is opened after 
the cooking cycle has been interrupted, because the relay RY1 
stays closed. Shown in the display is remaining time.
6.  MONITOR SWITCH CIRCUIT
  The monitor switch is mechanically controlled by the oven 
door, and monitors the operation of the monitored latch switch.
 1)  When the oven door is opened during or after the cycle of
   a cooking program, the monitored latch switch and stop
   switch must open their contacts (COM-NO) first. After that
   the contacts (COM-NC) of the monitor switch and monitored
   latch can be closed.
2)  When the oven door is closed, the contacts (COM-NC) of
   the monitor switch SW3 must be opened and the contacts
   (COM-NO) of monitor switch must be closed. After that the
   contacts (COM-NO) of the monitored latch switch and the
   stop switch are made closed, and the contacts (COM-NC)
   of the monitored latch switch are made open.
3)  When the oven door is opened and the contacts (COM-NO) 
   of the monitored latch switch remain closed, the fuse F8A
   will blow. Because the relay RY1 and monitor switch are
   closed and a short circuit is caused.
2. MEDIUM HIGH, MEDIUM, MEDIUM LOW, LOW
COOKING
When the microwave oven is preset for variable cooking power, 
the line voltage is supplied to the high voltage transformer 
intermittently within a 32-second time base through the relay 
contact which is coupled with the current-limiting relay RY2. The 
following levels of microwave power are given.
SETTING;
100P (HIGH)
32 sec. ON
70P
(MEDIUM HIGH)
Approx. 70%
100%
24 sec. ON
8 sec. OFF
14 sec. OFF
20 sec. OFF
26 sec. OFF
18 sec. ON
30P
(MEDIUMLOW)
10P
(LOW)
50P
(MEDIUMLOW)
Approx. 30%
Approx. 50%
Approx. 10%
12 sec. ON
6 sec. ON
NOTE: The ON/OFF time ratio does not exactly correspond to 
the percentage of microwave power, because approx. 
3 seconds are needed for heating up the magnetron 
filament.
5 - 1