R-890SLM - Sharp Home Appliance Service Manual (repair manual). Page 10

Read Sharp R-890SLM Service Manual online

R-890SLM
5 - 4
3. COOLING FAN OPERATION
OPERATION MODE
DEVICE
POWER CONTROL
PREHEAT
Cooling
60%
CONV. (OVEN)
Cooling fan 60% 60 min. then 100%
Others
Cooling fan 100%
After cooking
Cooling fan A cooling fan continues the rotation when Oven temperature is more than 120°C.
Then, it stops when it is less than 105°C
Indication
NOW COOLING is indicated during the cooling fan movement after operation is 
finished. (It isn’t indicated during a fan movement to stop on the way.)
4. CONVECTION POWER SETTING
4.1. PREHEATING
TEMP
250°C, 230°C, 220°C, 200°C, 180°C, 160°C, 130°C, 100°C, 70°C, 40°C
HEATING ELEMENT
TOP
100%
BOTTOM
100%
COOLING FAN
60%
CONV. FAN
0%
4.2. CONVECTION
TEMP
250°C 230°C 220°C 200°C 180°C 160°C 130°C 100°C 70°C
40°C
WITHOUT PREHEATING
HEATING 
ELEMENT
TOP
50%
40%
40%
30%
20%
10%
10%
10%
10%
10%
BOTTOM 100% 90%
80%
70%
70%
60%
50%
40%
30%
20%
WITH PREHEATING
HEATING 
ELEMENT
TOP
50%
40%
40%
30%
20%
10%
10%
10%
10%
10%
BOTTOM
90%
70%
60%
50%
50%
50%
50%
40%
30%
20%
COOLING FAN
60% 60min, then 100%
CONV. FAN
100%
0%
4.3. COMBI-1 (Micro + Conv)
TEMP
250°C 230°C 220°C 200°C 180°C 160°C 130°C 100°C 70°C
40°C
WITHOUT PREHEATING
HEATING 
ELEMENT
TOP
50%
40%
40%
30%
20%
10%
10%
10%
10%
10%
BOTTOM 100% 90%
80%
70%
70%
60%
50%
40%
30%
20%
WITH PREHEATING
HEATING 
ELEMENT
TOP
50%
40%
40%
30%
20%
10%
10%
10%
10%
10%
BOTTOM
90%
70%
60%
50%
50%
50%
50%
40%
30%
20%
MICRO
10%, 30%, 50%
COOLING FAN
100%
CONV. FAN
100%
0%
NOTE:  ✩The oven temp was checked by the thermometer when each stage is started.
 
If the oven temp is same or higher than 105°C, the oven was judged as “with preheating”.
 
When the oven temp is lower than 105°C or the cooling fan stops, the oven was judged as “without preheating”.
 
Micro and Top heating element can’t be on at the same time.