TEST PROCEDURES (CONT'D)
PROCEDURE
LETTER
COMPONENT TEST
D
TIMER MOTOR TEST
NOTE: *At the time of making these repairs,
make a visual inspection of the
varistor. Check for burned damage.
If any abnormal condition is detected,
replace the defective parts.
CARRY OUT 4R CHECKS.
D71
(F1)
(J2)
b
c
d
a
D72
R1
D1
(J1)
D70
RY1
M
1
3
2
4
CARRY OUT 3D CHECKS before any of the following timer tests.
TIMER MOTOR WITH VARI SWITCH
TIMER SWITCH- CONTACTS
Disconnect the leads from terminals described at following table. Connect an ohmmeter across terminals
described at following table.
Advance the timer and check that a short circuit reading is obtained on the meter.
Turn the timer back to the zero (0) position and check that an open circuit reading is obtained on the meter.
If these readings are not obtained then replace the timer.
Disconnecting and checking terminals
1 and 2
TIMER - MOTOR
Disconnect the leads from terminals described at following table. Connect an ohmmeter across the timer
motor winding, terminals are described at following table, and check that a reading of resistance described
at following table is indicated.
If this reading is not obtained then the timer is probably defective and should be replaced.
Disconnecting and checking terminals
3 and 4
Resistance of motor winding
approximately 22.2k ohms
CARRY OUT 4R CHECKS after any of the above tests.