R-205WM - Sharp Home Appliance Service Manual (repair manual). Page 10

Read Sharp R-205WM Service Manual online

R-205M - 10
Pin No.
Signal
I/O
Description
ON/OFF time ratio in Micro
cooking
(a. 32second time base)
MICRO
ON
OFF
COOK
100%
32sec.
0sec.
70%
24sec.
8sec.
50%
18sec.
14sec.
30%
12sec.
20sec.
10%
6sec.
26sec.
20 msec
H : 5V
L : 0V
11
D1
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY1).
The signal holds "L" level during micro-
wave cooking and "H" level while not cook-
ing. In other cooking modes (70%, 50%,
30%, 10%) the signal turns to "H" level and
"L" level in repetition according to the power
level.
12
D0
OUT
Terminal not used.
13
INT
IN
Signal to synchronize LSI with commercial power source frequency.
This is basic timing for all real time process-
ing of LSI.
14-16
P12-P10
OUT
Terminal not used.
17-20
P03-P00
IN
Terminal to change the Models and functions.
LSI(IXA128DR)
The I/O signals of the LSI(IXA128DR) are detailed in the following table.
DESCRIPTION OF LSI