R-205WM - Sharp Home Appliance Service Manual (repair manual). Page 12

Read Sharp R-205WM Service Manual online

R-205M - 12
COMPONENT REPLACEMENT
Note: After any service to the door;
(A) Make sure that monitored latch switch,latch switch
and monitor switch are operating properly.
(B) An approved microwave survey meter should be
used to assure compliance with proper microwave
radiation emission limitation standards
DOOR REPLACEMENT
1. CARRY OUT 3D CHECKS.
2. Remove choke cover taking care not to break clips.
3. Remove door assembly by lifting and easing it
forward.
4. On re-installation make sure the door is parallel with
the bottom line of the oven face plate and the latch head
pass through the latch holes correctly.
5. CARRY OUT 4R CHECKS.
NOTE : After any service to the door, the approved
microwave survey meter should be used to assure in
compliance with proper microwave radiation standards.
CHOKE COVER REMOVAL
1. Insert an iron plate (thickness of about 0.5mm) or
flat type screw driver to the gap between the choke
cover and door panel as shown figure to free the
engaged part.  The protect sheet may be used not
to damage the door panel.
2. Lift up the choke cover, now the coke cover is free.
Figure C-6.  Door Assembly Replacement and
Adjustment
NOTE: When carring out any repair to the door,
do not bend or warp the slit choke (tabs on
the door panel assembly) to prevent
microve leakage.
FLAT TYPE
SCREW-DRIVER
PROTECT BY TAPE
CHOKE
COVER
DOOR
PANEL
OUTER DOOR FILM
Removal
1. Remove  the door film from the clips on the door frame.
Installation
1. Attach  the door film to the clips on the door frame.
INNER DOOR FILM
Removal
1. Tear the door film from the door panel.
2. Now the door film is free.
Installation
1. Tear away the backing film.
2. Put the pasted side of the door film on the door
panel.
LATCH HEAD REMOVAL
1.
Remove the choke as above.
2. Unhook the spring and lift the latch head clear.
3. Replacement, the reverse of the above.
NOTE: When carring out any repair to the door,
do not bend or warp the slit choke (tabs on
the door panel assembly) to prevent
microve leakage.
DOOR ASSEMBLY
OUTER CASE
CABINET
LATCH HEADS
CHOKE
Door film
Finger tab
Backing film
Figure C-4.  Switches
1.
CARRY OUT 3D CHECKS.
2.
Disconnect the leads from all switches.
3.
Remove the one (1) screw holding the latch hook to the
oven cavity.
4.
Remove the latch hook.
5.
Push the retaining tab slightly and remove the switch.
LATCH HOOK
SW3: LATCH 
          SWITCH
SW1: MONITORED
          LATCH SWITCH
SW2:  MONITOR
           SWITCH
Tab
Tab
Post
Post
Tab
Post
MONITORED LATCH SWITCH, LATCH
SWITCH, AND MONITOR SWITCH REMOVAL
Page of 24
Display