Power Management
– 6 –
CHAPTER 5. POWER MANAGEMENT
Power Management Status Transition Chart
1
Factory setting
Status with no power supply. 
The CPU begins to run when the battery is inserted.
2
OFF Status (Boot Loader)
Initialization is carried out from the HW reset status and the
suspend status effected by the boot loader.
•  Reduction of OFF current may be achieved by suspending the
power supply and clock of unnecessary devices, and setting up a
CPU port.
3
RUN Status
Switch ON using the [Power] key.
•  A fatal check must be executed and if a fatal status is detected,
power must not be switched on.
Power must not be switched on if GPIO 17 (MAIN_BATT_LB) is
active (3 read calls at 10ms intervals), or if the battery compart-
ment lid is in unlock status.
•  In the RUN status, current consumption must be minimized by
switching off the power and clock requirements.
Additionally, it is recommended that application designs should
incorporate INFINTE as the TIME OUT for each thread (i.e. iop-
eration based on interrupt drive), enabling an environment where
the CPU can carry out IDLE processing.
•  When stored on the Flash disk, the registry information, favorites
and attached files are read out.
4
OFF Status (OS)
Transition to the suspend status may be accompished in one of the
two ways detailed below.
Note when a suspension is intialized under the conditions stated
below, Normally, resumption may be effected by input of the
[Power] key (exceptions: 
6
8
).
[Transition to the suspend status by pressing the [Power] key, or
upon request from the application]
•  Reduce OFF current by suspending the power supply and clock
of an unnecessary device, and setting up a CPU port.
•  Suspension is effected in the following sequence.
1. A buzzer sounds.
2. Register information, favorites and attached files are stored.
3. GwesPowerOffSystem is called.
The buzzer tone lets the user know that files are being saved and
that caution is required. At the same time, the buzzer also acts as a
warning to the user not to remove the batteries.
*
Note, the [Power] key suspend function is valid only when the [Power]
key is enabled in the register shown below.
Registry: SYSTEM
CurrentControlSet
Control
Power
Key: DisablePowerOff
0: [Power] key enabled.
1: [Power] key disabled.
OFF 
RUN 
IDLE 
Ex-factory 
shipping status
 
Battery 
inserted 
Power key
Full reset
 
SW RESET 
OFF
Switches to OFF after storing registry data, etc., on the flash disk while 
sounding the buzzer when in enabled status.
Full reset, backup 
battery discharge
 
 
 
 
 
 
Full reset
 
 
Boot Loader
Reset button: Only valid when enabled
Reset port: Unconditionally valid
4
5
3
6
5
2
1
8
6
7
HW RESET
[Low battery, battery compartment lid]
Switches to OFF while sounding the buzzer.
*Note, however, that when switching to RUN, resume processing is carried 
out via the ON routine in the boot loader.
 [Power button, application requirements]
YY
YY
YY
YY
Page of 49