UP-X200 (serv.man9). Service Manual - Sharp EPOS Service Manual (repair manual). Page 12

Read Sharp UP-X200 (serv.man9) Service Manual online

UP-X200
System Block Diagram
– 10 –
7-3. CHARGING CIRCUIT BLOCK DIAGRAM
In its initial status, the charging IC is ON (soft controlled) and is turned OFF without battery or at a fully charge state.
The charge current design value is 1A max, and uses the CC-CV method.
The UP-X200 features two main batteries in parallel and to increase the discharge ratio of these batteries, a software controlled switch to bypass the
diode is furnished. This switch is software controlled to ensure that the battery with the greater remaining capacity discharges, resulting in a more
equal wear on both batteries.
When set on the charger, this switch ensures that both batteries are off and that power is supplied to the system from the external power supply, sav-
ing wear on the main battery.
TC6393_VCC3
IC1308
3.3V
SA_PWR_EN
0V
I/O power supply for LCDC
VAB
(none)
3.5 - 4.3V
3.5 - 4.3V
Battery/external power supply output (Power supply source)
VCC_LCDP8V
IC601
+8V
LCD8V_PWR_EN
0V
+8V power supply for liquid crystal drive
VCC_LCDN4V
IC602
-4V
LCD8V_PWR_EN
0V
-4V power supply for liquid crystal drive
VCC_LCDN8V
Q601
-8V
LCDN8_PWR_EN
0V
-8V power supply for liquid crystal drive
VCC_LCD5V
Q603
5V
LCD5V_PWR_EN
0V
5V power supply for liquid crystal drive
VCC_LCD3V
IC605
3.3V
LCD3V_PWR_EN
0V
3.3V power supply for liquid crystal drive
Power Supply Name
Switch
(Regulator)
Output
Voltage
Control Signal
OFF
Application
Charging 
terminal  
Charging 
circuit 1
To power supply 
circuit
 
Input from AC adapter
Discharge 
switching signal
 
Charging 
circuit 2
Page of 49