Read Sharp UP-3515 (serv.man9) FAQ online
A. The group discount setting within department programming will only work
with Department keys and not PLU’s associated with that Department. You must
with Department keys and not PLU’s associated with that Department. You must
set each PLU to use Group Discount 1. This can be performed by range.
61. PLU Menus
Q. After selecting a product that is linked to a condiment table from within a PLU
menu the PLU menu does not stay down even though I have set the Menu to
Staydown. If I sell a PLU from within a PLU menu that is not linked to a
Q. After selecting a product that is linked to a condiment table from within a PLU
menu the PLU menu does not stay down even though I have set the Menu to
Staydown. If I sell a PLU from within a PLU menu that is not linked to a
Condiment list the PLU menu does staydown. Can this be changed.
A. Yes, Instead of using PLU menu’s you need to use Screens
62. GLU Print on BILL / GC Receipt
Q. Why is the GLU number not printing on the Bill/GC Rcpt?
Q. Why is the GLU number not printing on the Bill/GC Rcpt?
A. Select Program 2 > Settings > Optional > Print Select 1 and change Table#
Print Bill to YES.
63. Master Reset 13974682 & 11111111
Q. What is the difference between the two codes that can be used for the Master
Q. What is the difference between the two codes that can be used for the Master
Reset 1.
A. When using the 13974682 code any information relating to the License code
will be deleted from the terminal, license details such as expiry date will NOT be
will be deleted from the terminal, license details such as expiry date will NOT be
deleted if using the 11111111 code.
64. CENT name at CCD entry
Q. Where can I set the text of the CCD denomination amounts from 1 CENT to 1
PENCE.
PENCE.
A. PGM2/SETTINGS/MEDIA/CURRENCY MONEY/MONEY1 text change.
65. Plu Sales Report not showing any data
Q. I have Centralized PLU sales data set and an IRC system but PLU sales report
is blank?
Q. I have Centralized PLU sales data set and an IRC system but PLU sales report
is blank?
A. Ensure that
923 is set to 0010
The TLOG BUFFER on all satellites have at least 100 records set
The TLOG BUFFER on the master does not exist (Set to 0)
The PLU/EAN sales file on the Master Exists (Page 3 of PLU/EAN)
The PLU/EAN sales file on the slaves DO NOT exist (Page 3 of PLU/EAN)
After checking these settings perform an IRC SETUP for all machines