XE-A137 (serv.man2). XE-A137 Service Manual - Sharp ECR Service Manual (repair manual). Page 16

Read Sharp XE-A137 (serv.man2) Service Manual online

 
5-5 
 
c. 
Test result print 
When the test completion, following result is printed out 
< XE-A147 > 
 
 
 
 
 
 
 
 
<XE-A137> 
 
 
 
 
 
 
 
 
3-8) CLOCK TEST 
a. 
Test Procedure 
With the above key operation, the clock test is started. 
 
The clock data is read from CPU and displayed by real time. 
If count up is done  correctly, the result is  OK, push the [TL] key, 
test will finish with OK status. 
If not, push other than [TL] key, test will finish with NG status. 
 
b. 
Display 
 
 
 
 
 
 
 
 
c. 
Test result print 
When a test result is OK, following result is printed out 
 
 
 
 
 
 
When a test result is NG, following result is printed out 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3-9) Destination display / ROM version check 
a. 
Test Procedure 
With the above key operation, the Destination display / ROM 
version check is started. 
 
The CPU version and destination setting are read from CPU then 
displayed. The destination code is as follows; 
 
North America 
EU 
Japan 
Display 
Print 
 
If  the displayed destination is  correct, the result is OK, push the 
[TL] key, test will finish with OK status. 
If not, push other than [TL] key, test will finish with NG status. 
 
* In case of check sum is not correct, even if [TL] key is pushed, 
but, it may judged “NG”. Because of OK/NG is automatically 
judged by the program. 
 
b. 
Display 
  <North America> 
 
 
 
 
 
 
<EU> 
 
 
 
 
 
 
<Japan> 
 
 
 
 
 
c. 
Test result print 
When a test result is OK, following result is printed out 
 
 
 
 
 
 
When a test result is NG, following result is printed out 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  A/D   
1 HEAD VOLTAGE  X.XXV 
2 HEAD TEMP X.XXV 
3 BBATTERY VOLTAGE  X.XXV 
4 BATTERY VOLTAGE X.XXV 
5 BATTERY TEMP  X.XXV 
 
 
  A/D   
1 HEAD VOLTAGE  X.XXV 
2 HEAD TEMP X.XXV 
3 BBATTERY VOLTAGE  X.XXV 
Hour 
Minute 
Second 
Blink each 500msec 
 
  CLOCK              OK
 
 
  CLOCK              NG
 
ROM ver 
Destination 
code 
 
  DESTINATION U OK 
ROM ver.       1.00
 
 
DESTINATION  U OK 
ROM ver.       1.00
 
 
Page of 28
Display