4-4   
 
Mode switch layout 
 
 
 
c.  Function 
 
Turns the display off. No operations are possible   
REG 
Permit transaction entry 
 
Permit correction after final a transaction 
X/Flash 
Permits printing of sales reports and display the 
flash reports 
Z/PGM 
Permits printing and resetting of sales reports and 
programming 
 
3)  BATTERY 
a.  MEMORY BACK UP BATTERY 
For memory back up, the dry battery ULM-3 (3 pieces) are 
needed. 
1. 
Memory holding time: 
Approx. 1 year after New dry batteries are installed. 
(It is depend on the battery capacity) 
2. 
Battery exchange method: 
When the low battery symbol "L" lights up, replace the 
batteries (3 AA) replaced by the following method; 
1)   Power on the ECR. 
2)   Mode switch turn to "REG" mode. 
3)   Remove the OLD dry batteries (3 pieces). 
4)   The no-battery symbol "
L
" light up. 
5)   Insert the NEW dry batteries (3 pieces). 
6)    Confirm the low battery symbol "L" and no-battery 
symbol "
L
" is off. 
 
b.  LOW BATTERY 
Low battery indication will appear on the left side of display when 
the battery voltage is low. 
CASE 1: When sitting idle or after completion of transaction. The 
machine can indicate the low battery condition (Always) 
CASE 2: Low battery indication will not appear during key 
operations, but will appear after power up of the cash 
register. 
[Display sample] 
“0.00”:    Battery is OK.   
"L 0.00": Low battery (The batteries have to be replaced.) 
After finalization 
"F 12.34": Battery is OK.   
"L 12.34": Low battery ("L" indicate instead of "F".) 
c.  NO BATTERY 
If the user forgets to replace the battery and the battery voltage 
falls below a certain level, or if a power failure occurs with no 
batteries installed, the memory contents cannot be retained. The 
CPU judges it as no battery and performs the master reset. In this 
case, all the settings and registrations are cleared. If, however, the 
power is continuously supplied to the AC cord, the memory 
contents are retained. 
Low battery:   
Batteries are installed, but the voltage is 
low. Memory back up can be done. 
No battery:    Batteries are not installed or the voltage is extremely 
low. The master reset is executed when a power 
failure occurs, when the batteries are not properly 
changed. 
Low battery & No battery indication will appear at the most left 
position of display when the battery voltage is low. 
CASE 1:    When any numeric entry & item entry is not done or 
just after 
finalization. 
The machine can indicate the battery condition. (Always) 
CASE 2: When numeric entry or item entry is done. 
Battery condition is not appeared. 
Exceptionally, at the power is restored after power failure, 
the low battery & No battery indication will appear on the 
display only when the battery voltage is low. 
And the indication will disappear after any key entry. 
[Display sample] 
"      0.00" : Battery is OK. 
"L 0.00" : Low battery 
"
L
 0.00" : No battery   
After finalization 
"F 12.34": Battery is OK. 
"L 12.34": Low battery ("L" indicate instead of "F".) 
"
L
 12.34": No battery ("L" indicate instead of "F" 
 
 