XE-A137 (serv.man2). XE-A137 Service Manual - Sharp ECR Service Manual (repair manual). Page 12

Read Sharp XE-A137 (serv.man2) Service Manual online

 
5-1 
 
CHAPTER 5. DIAGNOSTICS 
1.  XE-A137/XE-A147 
1)  Diagnostic menu 
 
DIAG menu 
DESCRIPTION 
1  Mode switch test 
To check the mode key function 
2  Key test 
Keyboard check 
3  Display test 
To check a display 
4  Drawer test 
To check a drawer opening 
5  Printer test 
Printer test 
6  Printer paper sensor test  To check a printer paper sensor 
7  AD conversion level test  AD conversion check 
8  CLOCK test 
To check the clock on CPU 
Destination display / 
ROM version 
To check the Destination setting and 
ROM version 
10  SD card test 
To check the SD-card write protection 
11  RS232C (XE-A147 only)  To execute the loopback test 
12  ROM (Japan only) 
To check the ROM for Japanese 
characters 
13  RAM 
To execute the RAM read write test 
 
2)  Entering procedure 
It is possible to enter the DIAG mode with following procedure;   
1. 
To set the mode switch to Z/PGM position 
2. 
To input the job code in accordance with below list 
3. 
To push the PO key 
4. 
Start the Diagnostic mode 
 
DIAG menu 
Mode key 
position 
Key code 
Mode switch test 
Z/PGM 
‘1’ + PO key 
Key test 
Z/PGM 
‘2’ + PO key 
Display test 
Z/PGM 
‘3’ + PO key 
Drawer test 
Z/PGM 
‘4’ + PO key 
Printer test 
Z/PGM 
‘5’ + PO key 
Printer Paper sensor test 
Z/PGM 
‘6’ + PO key 
AD conversion level test 
Z/PGM 
‘7’ + PO key 
CLOCK test 
Z/PGM 
‘8’ + PO key 
Destination display / ROM 
version 
Z/PGM 
‘9’ + PO key 
SD card test 
Z/PGM 
‘10’ + PO key 
RS232C (XE-A147 only) 
Z/PGM 
‘11’ + PO key 
ROM check (Japan only)   
Z/PGM 
‘12’ + PO key 
RAM check 
Z/PGM 
‘13’ + PO key 
 
 
 
 
 
 
 
 
3)  Description 
3-1)  MODE KEY SWITCH 
a. 
Test Procedure 
Change over the mode switch as follows. If the mode switch data 
in the proper sequence is not read with the above operation, an 
error is printed. 
To cancel this test mode, set the mode switch to any a position 
other than [Z/PGM] to [Z/PGM]. In this case, the completion print is 
performed. 
During the test, the display indicates hard codes which correspond 
to the switch position. 
 
The mode switch is set to the “OFF position”, it will no-display. 
 
<Note>   
In the test, the mode key should be fixed over 1second in each 
position. 
 
b. 
Mode switch operation 
MODE: [Z/PGM]  →  [X/FLASH]  →  [REG]  →  [OFF]  →  [VOID] 
 
c. 
Display 
   
    
 
 
 
 
    
 
 
 
 
   
 
 
 
 
   
 
 
 
 
 
 
 
 
[Z/PGM] 
[X/FLASH] 
[REG] 
[OFF] 
[VOID] 
Page of 28
Display