XE-A137 (serv.man2). XE-A137 Service Manual - Sharp ECR Service Manual (repair manual). Page 19

Read Sharp XE-A137 (serv.man2) Service Manual online

 
5-8 
 
2.  XE-A107 
1)  Diagnostic menu 
 
DIAG MENU 
DESCRIPTION 
1  Mode switch test 
To check the mode key function 
2  Key test 
Keyboard check 
3  Display test 
To check a display and buzzer 
4  Drawer test 
To check a drawer opening 
5  Printer test 
Printer test 
6  CPU ver. display 
CPU version check 
7  Battery level test 
Battery condition check 
8  CLOCK test 
To check the clock on CPU 
9  Destination display 
To check the Destination setting 
 
 
2)  Entering procedure 
It is possible to enter the DIAG mode with following procedure;   
1. 
To set the mode switch to Z/PGM position 
2. 
To input the job code in accordance with below list 
3. 
To push the PO key 
4. 
Start the Diagnostic mode 
 
DIAG menu 
Mode key 
position 
Key code 
Mode switch test 
Z/PGM 
‘1’ + PO key 
Key test 
Z/PGM 
‘xxxx2’ + PO key 
Display test 
Z/PGM 
‘3’ + PO key 
Drawer test 
Z/PGM 
‘4’ + PO key 
Printer test 
Z/PGM 
‘5’ + PO key 
CPU ver. display 
Z/PGM 
‘6’ + PO key 
Battery level test 
Z/PGM 
‘7’ + PO key 
CLOCK test 
Z/PGM 
‘8’ + PO key 
Destination display 
Z/PGM 
‘9’ + PO key 
 
3)  Description 
3-1)  MODE KEY SWITCH 
a. 
Test Procedure 
Change over the mode switch as follows. If the mode switch data 
in the proper sequence is not read with the above operation, an 
error is printed. 
To cancel this test mode, set the mode switch to any a position 
other than Z/PGM to Z/PGM. In this case, the completion print is 
performed. 
During the test, the display indicates hard codes which correspond 
to the switch position. 
 
The mode switch is set to the “OFF position”, it will no-display. 
 
<Note>   
In the test, the mode key should be fixed over 1second in each 
position. 
 
 
 
 
 
b. 
Mode switch operation 
MODE: [Z/PGM]  →  [X/FLASH]  →  [REG]  →  [OFF]  →  [VOID] 
 
 
c. 
Display 
 
   
    
 
 
 
 
    
 
 
 
 
   
 
 
 
 
   
 
 
 
 
 
 
 
 
 
 
d. 
Test result print 
When a test results is OK, following result is printed out 
 
 
 
 
When a test result is NG, following result is printed out. 
 
 
 
 
 
 
 
 
 
 
 
[Z/PGM] 
[X/FLASH] 
[REG] 
[OFF] 
[VOID] 
 
01
  
 
 
----01  
 
Page of 28
Display