9. RS232 Channels
There are 2 ports as standard on the UP600/700.
Ch1 is a standard 9 way D Type (This does not have 5v from out of the box, a switch
is provided to supply the 5v.
The maximum speed of this channel is 38400
Ch2 is an RJ45 connection.
Maximum baud rate for this channel is 115200 but there is no 5v supply.
Channel 2 (only Ch2) is also used for send and receive data from ECR to ECR., or
PC to ECR.