3. Installation procedure
1) Connect the internal cable to the interface PWB unit. 
Α
In-Line cable
1
Connect the branch cable 
1
 to the BNC-T connector 
2
.  (Fig. 1)
Fig. 1
2
Connect the BNC-T connector to the internal cable. (Fig. 2)
Fig. 2
Β
RS232 cable
Fig. 3
Be sure to install the core 
3
 (RCORF6658RCZZ) on RS-232C
cable. (Fig. 3)
2) To install two interface PWB’s, follow the next steps. (When in-
stalling the ER-A6IN and the ER-A5RS)
1
Insert two spacers 
α
 and connect the connectors of the interface
PWB together (Fig.4).
Make sure the spacer is mounted properly to insure proper
connection.
2
Secute the brackets 
δ
 with the screws 
β
 and 
χ
 (LX-
BZ6774RCZZ: Self tap screw). (Fig. 4)
Fig. 4
3) Remove two rear cover holding screws and remove the rear cover
4
  (Fig.5).
The interface PWB needs to be inserted into the left side slot
as seen from rear.
Tilt up the popup dispalay when removing the rear cover.
4) Break open the knockout  
5
  of the rear cover  
4
  (Fig.5).
After beraking open the knockout 
5
, file off the new hole.
5) Insert the interface PWB 
6
 onto the connector of the main PWB
7
, and fasten the bracket to the main chassis using screws 
8
(LX-BZ6774RCZZ: Self tap screw) (Fig.5).
Insert both sides of the interface PWB along the guides of the
bottom cabinet.
2
1
3
 RCORF6658RCZZ
a
c
: LX-BZ6774RCZZ
: LX-BZ6774RCZZ
b
d
d