SM-SX100 (serv.man2) - Sharp Audio Service Manual (repair manual). Page 8

Read Sharp SM-SX100 (serv.man2) Service Manual online

SM-SX100
– 8 –
Figure 8-2
Figure 8-1
Note 1:
Positioning the volume joints
1. Rotate the sub volume shaft (inside of the set) so that the
flat side faces upward. Fasten the joints in numerical order
as shown in the in the figure.
2. Rotate anticlockwise both the main and sub shafts to mini-
mum level.
3. Slide the connecting shaft until it hits the joint coupling
sleeve.
4. Rotate the joint coupling and connecting shaft so that the
hexagonal screws face the direction of 12 and 9 o'clock.
Fasten the screw that face 12 o'clock.
5. Rotate the shaft and fasten the other hexagonal screws.
6. Rotate the volume shaft so that the flat side faces downward.
Fasten the hexagonal screw from below.
1 (Fasten)
2 (Fasten)
Sub Volume
Joint
Coupling
Fasten
Fasten
Fasten
Fasten
Keep the default setting,
 "each interval = 1 mm."
Sleeve
Hub
Hub
Fasten
Volume
Knob
Volume Connecting Shaft
Joint Coupling