SM-SX100 (serv.man2) - Sharp Audio Service Manual (repair manual). Page 9

Read Sharp SM-SX100 (serv.man2) Service Manual online

SM-SX100
– 9 –
ADJUSTMENT
Measure the noise distribution between the set output terminals (Lch+, Lch- and Rch+, Rch-), and adjust VRA1 to VRA4. The VRA
adjustment sequence is the same as that of the offset voltage adjustment.
Measuring instrument: Yokokawa Electric brand SA2400
Measurement range : Refer to Fig. 9-2.
Adjustable range: 
1
 250Hz to 100kHz within 
±
3dB from the standard noise curve
2
 (Noise strength of 125Hz) — (Noise strength of 250Hz)      20dB
AC POWER
SUPPLY
UNIT
Specter 
Analyzer
Speaker terminal
Apply the analyzer between Lch+ and Lch-,
and between Rch+ and Rch-.
Figure 9-1
Standard noise floor curve
(Frequency range 1)
Figure 9-2
20dBV ¨ ”
Page of 72