AY-XP08CR
AY-XP10CR
AY-XP13CR
FOR OUTDOOR UNIT [AE-X08CR / AE-X10CR / AE-X13CR]
CAUTION : DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY 
SERVICING
1. Loose a screw fixing the side cover.
Right side view
Left side view
Right side view
Left side view
Front view
2. Loose the unit to unit cord.
3. Loose a screw fixing the cord clamp.
4. Loose 4 screws fixing the top panel.
5. Loose 6 screws fixing the front panel.
6. Cut 4 nylon bands.
7. Disconnect following connectors and each wire.
 Choke coil(two terminal)
 Fan motor
 Thermistor
 Reverse valve