3. Connect the EVR Extender board (VFK1694) to EVR connector on EVR connect C.B.A. in camera recorder.
Then make sure that the direction of the Extender Board is correct as shown in Figure.
4. Supply DC6V-9V to the Measuring Board (VFK1308P). Please use the DC cable (VJA0941) and AC Adaptor to
supply DC voltage to Measuring Board.
5. Connect a 9 pin RS-232C cable between the Measuring Board and RS-232C connector on Personal Computer
as shown in Figure.
6. Unless otherwise specified on the message of the EVR software or this adjustment procedure, set the switches
on the Measuring Board as shown in the table below.
NAME SETTING
POSITION
RS232C SEL (SW101)
D-SUB
VTR TEST (SW103)
NORMAL
BST TEST (SW104)
NORMAL
SW107 CENTER
position
SW108 H
SW105 H
SW106 OFF
FLUSH1 (SW102)
SW105 H
SW106 OFF
FLUSH1 (SW102)
NORMAL
FLUSH2 (SW109)
NORMAL
EVR connector
When the VFK1694 connect to EVR connector, be careful direction of
VFK1694. Please follow as shown in the figure.
VFK1694. Please follow as shown in the figure.