MECH-20
2. Remove 2 screws (P) and Cylinder Base Unit with
S and T Boat Units. Then remove S and T Boat
Units from the Cylinder Base Unit.
Units from the Cylinder Base Unit.
Figure 2-3-22
(Note of installation)
After install the Cylinder Base Unit move, S and T
Boat to loading completed position by finger and turn
the Mode Gear clockwise until half loading position.
Then connect the locking portion (A) and (B).
2-3-15. S1 Arm Unit
1. Turn the Mode Gear fully clockwise. Remove the
Cut Washer (Q) and S1 Arm Unit.
Figure 2-3-23
2-3-16. Radon Plate, Radon Arm
& T1 Arm Unit
1. Unscrew 2 screws (R) and remove Radon Plate.
Figure 2-3-24
2. Unscrew screw (S) and remove Radon Arm Unit.
Figure 2-3-25
3. Remove the T1 Arm Unit.
(Note of installation)
When installing the T1 Arm Unit, the projection ( j ) on
the Radon Arm Unit is aligned to guide ( j' ) on the T1
Arm Unit by pushing the T1 Arm Unit.