MECH-13 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 10 
 
 
 
 
 
 
 
 
 
 
 
 
10. Press “SPACE” key to perform the Peak Hold in 30 seconds when linearity is displayed. 
11. After finish the Peak Hold, press “SHIFT” and “ } ” key simultaneously on the Key Board, then the numerical 
values of “Linearity” and “Waving” is displayed on left lower portion of screen. And confirm the numerical 
value of “Linearity” is in the specification. If the “Linearity” is out of specification adjust height of S1 and T1 
post. 
12.  After this measurement is finished, press the ESC key to return to the main menu. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
POINT : 
The part of left side of waveform (entrance side) is adjusted by height of S1 post and part of right side of 
waveform (exit side) is adjusted by height of T1 post. 
Lower part of above waveform of figure is displayed lead of Cylinder. 
When the post driver is remove from upper part of post, linearity waveform is changed. 
After finish this adjustment, eject the tape and insert the tape again for confirm the shape of linearity waveform 
does not changed. 
Adjust Linearity 
into this area. 
Confirm this value 