1-6-4. LISTA Sensitivity Detection
TP
In case of use VFK1409A
F2 : ATF-ERR (VFK1409A), TP2 : TRG/HSW (VFK1409A), GND : GND (VFK1409A)
In case of use VFK1409S
F2 : ATF-ERR (VFK1409S), TP2 : TRG/HSW (VFK1810), GND : GND (VFK1409S)
VTR MODE
PLAY
ADJ. MODE
Refer to below explanation
TAPE
VFM3000EDS (DV LISTA)
SPEC.
40 mV /
µ
m to 120 mV /
µ
m
1. Set the camera recorder to VCR mode.
2. Insert the DV Alignment Tape (VFM3000EDS) to the camera recorder.
3. Press the MENU button while pressing the ADUB button and the OPERATION LEVER in REW direction at the
same time, then open the “VCR FUNCTION MENU”.
4. Open
the
“7. ADJUST MENU” in “VCR FUNCTION MENU”.
5. Select the item “ATF GAIN” and press the OPERATION LEVER.
6. Message “NOW SERVO ADJUST PUSH MENU TO RETURN” is appeared on screen and tilt the
6. Message “NOW SERVO ADJUST PUSH MENU TO RETURN” is appeared on screen and tilt the
OPERATION LEVER in UP(PLAY) direction to playback the tape.
7. Press MENU button to return “ADJUST MENU” screen.
8. Select
8. Select
item
“<1> Sensitivity Measurement” on the LISTA main menu, and press “ENTER”.
9. Then the tape is played back (tape speed : 101.2%) automatically, and message “1.2% Speed…” appears an
the screen.
10. Press the ENTER key, and then start measurement of the sensitivity value.
11. Confirm that the sensitivity value is with in specification, when the message “<<Sensitivity Measurement
11. Confirm that the sensitivity value is with in specification, when the message “<<Sensitivity Measurement
Finish>>”.
Figure 9
<<Sensitivity Measurement Finish>>
Sensitivity 72.95
(mV/um)
Sens.1
65.43 (mV/um)
Sens.1
85.48 (mV/um)
Confirm that the value of Sens.Value1
and Sens.Value2 in specification
and Sens.Value2 in specification
Select at Sensitivity Detection.