PT-VW340Z, PT-VW340ZD, PT-VX410Z, PT-VX410ZD, PT-VX46EA, PT-VX406EA - Panasonic Projector Service Manual (repair manual). Page 22

Read Panasonic PT-VW340Z / PT-VW340ZD / PT-VX410Z / PT-VX410ZD / PT-VX46EA / PT-VX406EA Service Manual online

INF-16
SECTION 1 SERVICE INFORMATION
4. 2. 2. 2. Command transmission method
Transmit using the following command formats.
  Transmitted data
Header
Data section
Termination symbol
Hash value
(Refer to 4. 2. 2. 1. -3)
'0'
0x30
'0'
0x30
Control command
(ASCII string)
(CR)
0x0d
32 bytes
1 byte
1 byte
Undefined length
1 byte
  Received data
Header
Data section
Termination symbol
'0'
0x30
'0'
0x30
Control command
(ASCII string)
(CR)
0x0d
32 bytes
1 byte
Undefined length
1 byte
  Error response
Error message
Termination symbol
“ERR1” 
 
Undefined control command
“ERR2” 
 
Out of parameter range
“ERR3” 
 
Busy state or no-acceptable period
“ERR4” 
 
Timeout or no-acceptable period
“ERR5”
Wrong data length
“ERRA” 
 
Invalid password
(CR)
0x0d
4 byte
1 byte
Example: Query Power "QPW"
  1. Connects to the projector
    IP = 192.168.0.8  
port = 1024
  2. Receives a response
   Response = "NTCONTROL 1 1aa6c14e" + (CR)
    "1aa6c14e" = 8 bytes random characters
 3. Generates a hash value (message digest) from "admin1:panasonic:1aa6c14e" by using the MD5 algorithm.
    "admin1" = Administrator authority user-name
    "panasonic" = Password corresponding to "admin1"
   Hash value = "01466bc27ed8c0b7e607471580c55953"
  4. Transmits the command
   Transmission data = "01466bc27ed8c0b7e607471580c5595300QPW" + (CR)
  5. Receives a response.
    Reception data = "00000" + (CR)
  6. Disconnects the connection with the projector.
Page of 118
Display

Click on the first or last page to see other PT-VW340Z / PT-VW340ZD / PT-VX410Z / PT-VX410ZD / PT-VX46EA / PT-VX406EA service manuals if exist.