Read Panasonic PT-EX12KU / PT-EX12KE Service Manual online
-10-
This projector provides the following circuit protections to operate in safety. If the abnormality occurs inside the pro-
jector, it will automatically turn off by operating one of the following protection circuits.
jector, it will automatically turn off by operating one of the following protection circuits.
Circuit Protections
Fuses are located inside of the projector. If all the indicators are not lighting,
the fuse (F2601) may be opened. If the STAND-BY indicator is lighting and
others are blinking, one of the fuses (F2602) may be opened. If fuse (F2602)
opens, the power supply to the LAMP1/LAMP2 will be cut off.
Check the fuses as following steps.
The fuses should be used with the following type;
the fuse (F2601) may be opened. If the STAND-BY indicator is lighting and
others are blinking, one of the fuses (F2602) may be opened. If fuse (F2602)
opens, the power supply to the LAMP1/LAMP2 will be cut off.
Check the fuses as following steps.
The fuses should be used with the following type;
Location : F2601
Fuse Part No. : K5E153BZA003
TYPE 15A 250V FUSE
0215015.MXEP, LITTEL
Fuse Part No. : K5E153BZA003
TYPE 15A 250V FUSE
0215015.MXEP, LITTEL
How to replace the fuses
1. Remove the cabinet top, main board following to "Me-
chanical disassembly".
2. Remove the fuses F2601, F2602 on the line filter board.
To install the fuses, take reversed step in the above.
Fuses (F2601, F2602)
Location : F2602
Fuse Part No. : K5E632BZA003
TYPE 6.3A 250V FUSE
021506.3MXEP, LITTEL
Fuse Part No. : K5E632BZA003
TYPE 6.3A 250V FUSE
021506.3MXEP, LITTEL
Line filter