-14-
The projector provides the detection circuits of the power failure and the fan lock. When the detection circuit detects 
an error at the power supply line or at the fan operation circuit, the projector will turn into the standby mode to protect 
the other circuits defective.
Circuit Protections
Power failure, fan lock and filter error detection
CAUTION
DO NOT LEAVE THE PROJECTOR WITH THE AC POWER CORD 
CONNECTED UNDER AN ABNORMAL CONDITION. IT MAY RE-
SULT IN FIRE OR ELECTRIC SHOCK.
The projector is shut down; and the <STANDBY> indicator 
is lighting and other indicators are blinking.
When the projector detects an abnormal condition (Power supply lines failure 
, fans failure), it will be automatically shut down to protect the inside of the 
projector and the <STANDBY> indicator lights on and other indicators blink. 
In this case, unplug the AC power cord and plug it, and then turn on the pro-
jector once again to verify operation. If the projector cannot be turned on and 
these indicators are still lighting and blinking, unplug the AC power cord. See 
the troubleshooting chapter.
STANDBY indicator lights 
on and other indicators 
blink.
Indicators