Read Panasonic PT-EX12KU / PT-EX12KE Service Manual online
-13-
The projector provides 2 temperature sensor ICs, 1 sensor on the main board and 1 sensor on the ex temp board,
and 1 wind sensor on the intake duct. The sensor ICs monitor surrounding temperature of the panels/prism, and
surrounding temperature of the intake duct, and the wind sensor monitors airflow passed through the air filter in the
intake duct.
- Temperature sensor (IC8856) on the main board for monitoring the surrounding temperature of B-panel.
- Temperature sensor (IC8811) on the ex temp board for monitoring the surrounding temperature of the intake duct.
- Wind sensor (S901) on the filter box.
and 1 wind sensor on the intake duct. The sensor ICs monitor surrounding temperature of the panels/prism, and
surrounding temperature of the intake duct, and the wind sensor monitors airflow passed through the air filter in the
intake duct.
- Temperature sensor (IC8856) on the main board for monitoring the surrounding temperature of B-panel.
- Temperature sensor (IC8811) on the ex temp board for monitoring the surrounding temperature of the intake duct.
- Wind sensor (S901) on the filter box.
Circuit Protections
Temperature sensors, wind sensors
The projector is shut down and the <WARNING TEMP.> indi-
cator is blinking red.
When the temperature inside the projector reaches a certain level, the
<WARNING TEMP.> indicator starts blinking. If the temperature rises more-
over, the projector will be automatically shut down to protect the inside of
the projector, and the <WARNING TEMP.> indicator is blinking fast and the
<POWER> indicator turns off. When the projector has cooled down enough
(to its normal operating temperature), the <POWER> indicator turns on and
the projector can be turned on again by pressing the
<WARNING TEMP.> indicator starts blinking. If the temperature rises more-
over, the projector will be automatically shut down to protect the inside of
the projector, and the <WARNING TEMP.> indicator is blinking fast and the
<POWER> indicator turns off. When the projector has cooled down enough
(to its normal operating temperature), the <POWER> indicator turns on and
the projector can be turned on again by pressing the
button.
✔
Note:
• The <WARNING TEMP.> indicator continues to blink even after the tem-
perature inside the projector returns to normal. When the projector is turned
on again, the <WARNING TEMP.> indicator stops blinking.
on again, the <WARNING TEMP.> indicator stops blinking.
WARNING TEMP.
blinking red
blinking red
Check the items below
- Remove dust around the air filter.
- Ventilation slots of the projector are blocked. In such an event, reposition the
- Remove dust around the air filter.
- Ventilation slots of the projector are blocked. In such an event, reposition the
projector so that ventilation slots are not obstructed.
- Check if projector is used at higher temperature place (Norma; operating
temperature is 0 to 40 ºC or 32 to 104 ºF).
IC8856
(Behind)
(Behind)
S901
Wind sensor
Wind sensor
IC8811
Indicators
Click on the first or last page to see other PT-EX12KU / PT-EX12KE service manuals if exist.