PT-DZ8700U, PT-DS8500U, PT-DW8300U, PT-DZ110XE, PT-DS100XE, PT-DW90XE (serv.man11) - Panasonic Projector Service Manual (repair manual). Page 18

Read Panasonic PT-DZ8700U / PT-DS8500U / PT-DW8300U / PT-DZ110XE / PT-DS100XE / PT-DW90XE (serv.man11) Service Manual online

PT-DZ8700U / PT-DS8500U / PT-DW8300U / PT-DZ110XE / PT-DS100XE / PT-DW90XE
 
INF-12 
                    Example: Query Power "QPW" 
1. Connects to the projector. 
IP = 192.168.0.8, Port number = 1024 
2. Receives a response. 
Response = "NTCONTROL 1 1aa6c14e" + (CR) 
"1aa6c14e" = 8 bytes random characters 
3. Generates a hash value (message digest) from "admin1:panasonic:1aa6c14e" by using the MD5. 
"admin1" = Administrator authority user-name 
"panasonic" = Password corresponding to "admin1" 
Hash value = "01466bc27ed8c0b7e607471580c55953" 
4. Transmits the command. 
Transmission data = "01466bc27ed8c0b7e607471580c5595300QPW" + (CR) 
5. Receives a response. 
Reception data = "00000" + (CR) 
6. Disconnects the connection with the projector. 
 
4.2.3 When WEB CONTROL Admin Password is not set (Unprotected Mode) 
4.2.3.1. Connection 
                1. Access IP address and the port number (default = 1024) of the projector, then connect to the projector with them. 
            P address and the port number can be accessed from the menu of the projector. 
              - IP address: MAIN MENU → NETWORK → NETWORK STATUS 
                            - Port number: MAIN MENU  → NETWORK → NETWORK CONTROL → COMMAND PORT 
                2. Receive a response message. 
            Response Message 
 
 
 
 
 
 
4.2.3.2. Method of Command Transmission 
        Transmits command by the following format. 
                        Transmission Data 
Header 
Data section 
End character 
‘ 0 ’ 
0x30 
‘ 0 ’ 
0x30 
Control command 
(ASCII character string) 
(CR) 
0x0d 
1 byte 
1 byte 
Undefined length 
1 byte 
                        Reception Data 
Header 
Data section 
End character 
‘ 0 ’ 
0x30 
‘ 0 ’ 
0x30 
Control command 
(ASCII character string) 
(CR) 
0x0d 
1 byte 
1 byte 
Undefined length 
1 byte 
                        Error Response 
Error Message 
End character 
"ERR1"    Command format error 
"ERR2"    Out of parameter 
"ERR3"    Busy or unavailable time  
"ERR4"    Timeout or unavailable time 
"ERR5"    Data length error 
"ERRA"    Invalid password 
(CR) 0x0d 
(CR) 0x0d 
(CR) 0x0d 
(CR) 0x0d 
(CR) 0x0d 
(CR) 0x0d 
4 bytes 
1 byte 
                    Example: Query Power "QPW" 
1. Connects to the projector. 
IP = 192.168.0.8, Port number = 1024 
2. Receives a response. 
Response = "NTCONTROL 0" + (CR) 
3. Transmits the command. 
Transmission data = "00QPW" + (CR) 
4. Receives a response. 
Reception data = "00000" + (CR) 
5. Disconnects the connection with the projector. 
 
    4.3. Control commands List 
 
                    Please refer to "SECTION6(control commands)". 
Data section 
Space 
Mode 
End character 
"NTCONTROL" 
‘  ‘ 
‘ 1 ‘ 
(CR) 
(ASCII character string) 
0x20 
0x30 
0x0d 
9 bytes 
1 byte 
1 byte 
1 byte 
Mode:0 = Unprotected mode 
Page of 78