INF-11 
    4.2. Control through LAN
 
            Connection and the method of command transmission are different according to the mode (the setting of Admin password 
            on WEB CONTROL). Control according to the procedure in 4.2.2. on the protection mode (the password is set), and 
      according to the procedure in 4.2.3. on the unprotected mode (the password is not set). 
 
4.2.1 Examples of Connection
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
4.2.2 When WEB CONTROL Admin Password is set (Protection Mode) 
4.2.2.1. Connection 
                1. Access IP address and the port number (default = 1024) of the projector, then connect to the projector with them. 
            P address and the port number can be accessed from the menu of the projector. 
              - IP address: MAIN MENU → NETWORK → NETWORK STATUS 
                            - Port number: MAIN MENU  → NETWORK → NETWORK CONTROL → COMMAND PORT 
                2. Receive a response message. 
            Response Message 
 
 
 
 
 
 
        3. Generate 32 bytes hash value (message digest) from the following data by using the MD5 (Message Digest Algorithm 5). 
                        ″xxxxxx:yyyyy:zzzzzzzz″ 
              - xxxxxx: Administrator authority user-name on WEB CONTROL [default = "admin1"] 
              - yyyyy: Password corresponding to above-mentioned user-name (admin1) [default = "panasonic"] 
              - zzzzzzzz: 8 bytes random characters obtained from the response message 
              - : (colon): Separator 
4.2.2.2. Method of Command Transmission 
        Transmits command by the following format. 
                        Transmission Data 
Header 
Data section 
End character 
Hash value 
(Refer to the step 3 in 4.2.1.1.) 
‘ 0 ’ 
0x30 
‘ 0 ’ 
0x30 
Control command 
(ASCII character string) 
(CR) 
0x0d 
32 bytes 
1 byte 
1 byte 
Undefined length 
1 byte 
                        Reception Data 
Header 
Data section 
End character 
‘ 0 ’ 
0x30 
‘ 0 ’ 
0x30 
Control command 
(ASCII character string) 
(CR) 
0x0d 
1 byte 
1 byte 
Undefined length 
1 byte 
                        Error Response 
Error Message 
End character 
"ERR1"    Command format error 
"ERR2"    Out of parameter 
"ERR3"    Busy or unavailable time  
"ERR4"    Timeout or unavailable time 
"ERR5"    Data length error 
"ERRA"    Invalid password 
(CR) 0x0d 
(CR) 0x0d 
(CR) 0x0d 
(CR) 0x0d 
(CR) 0x0d 
(CR) 0x0d 
4 bytes 
1 byte 
 
 
Data section 
Space 
Mode 
Space 
Random characters 
End character 
"NTCONTROL" 
‘  ‘ 
‘ 1 ‘ 
‘  ‘ 
“zzzzzzzz” 
(CR) 
(ASCII character string) 
0x20 
0x30 
0x20 
(Hexadecimal ASCII code) 
0x0d 
9 bytes 
1 byte 
1 byte 
1 byte 
8 bytes 
1 byte 
Projector 
LAN switch
Computer
LAN cable (straight) 
LAN cable (straight) 
Note: Use a proper LAN cable which is suitable for the PC to connect SERIAL connector and the PC.
Mode:1 = Protection mode 
Page of 78
Display