PT-DZ570U, PT-DZ570E, PT-DW530U, PT-DW530E, PT-DX500U, PT-DX500E (serv.man8) - Panasonic Projector Service Manual (repair manual). Page 23

Read Panasonic PT-DZ570U / PT-DZ570E / PT-DW530U / PT-DW530E / PT-DX500U / PT-DX500E (serv.man8) Service Manual online

<
PT-DZ570U/PT-DW530U/PT-DX500U/PT-DZ570E/PT-DW530E/PT-DX500E>
6 Troubleshooting
  6. 1. Shutdown system
When something wrong such as stop of fan happens, the projector has a function to be on standby immediately.
Note: In **, count down value of 10 to 1 is displayed . 
Optical module error.
Heat sink attachment error.
Clogged ventilator.
high altitude mode is not on.
58 degrees
"TEMPERATURE WARNING "
56 degrees "Warning cancel
 LAMP LED blinks once
Filter clogging
Intake window is closed.
Lamp is not installed
Cable for lamp memory has bad contact or
connection.
 TEMP LED blinks once
Clogging temperature sensor:
Over the threshold value
 No flashing or blinking
Optical module temperature
sensor:
More than 60 degrees
 TEMP LED Blinks 2
times
 (Warning: TEMP LED
lights)
Each FAN sense signal:
Rotation speed is slower than
50% of target for more than 5
Intake air temperature sensor:
More than 48 degree C
(High altitude mode: more than
43 degree C)
Ballast block:
Over 115±5 degrees C
(Returns with 80±15 degree C)
 TEMP LED Blinkls 3 times
Optical module temperature
sensor:
After lamp lighting, less than 2
degrees C for more than 5
No Fan sense signal
 STANDBY/ON LED
 blinks in red 3 times
 LAMP LED lights
 STANDBY/ON LED: Red
 TEMP LED: Lights
Intake air temperature sensor:
Under -20 degree C
Optical block temperature
sensor
Under -20 degree C
Lamp memory (EEPROM)
communication:
No response(ACK)
 LAMP LED blinks 3 times
Exhaust temperature sensor:
More than 74 degrees C
Interlock SW
Exhausting fan rotation speed is
slower than 50% of target for
Failed making lamp ON, lamp abnormal
condition
Ballast block faulty
Hot restart
Optical module temperature is low.
Adjust the setting circumstances.
Monitor LED indication
Fan rotation problem
OSD warning
Connector is disconnected.
Fan rotation problem
Exhausting temperature sensor
Under -20 degree C
46 degrees (high altitude 41
degrees) "TEMPERATURE
WARNING"
44 degrees (high altitude 39
Shutdown detection
70 degrees
"TEMPERATURE WARNING "
68 degrees "Warning cancel"
Lamp hours is over 2000 hours.
(Shuts down after 10 min.)
Intake air tempereture problem
Filter clogging
High temperature of environment
Intake air window is closed.
Exhaust temperature error.
Closed ventilator.
Deteriorating exhaust fan.
High altitude mode is not on.
Lamp usage hour is over the guideline.
Lamp status:
Lamp is off during the status
other than normal one
Connection problem with Intake air
temperature sensor
Faulty temperature sensor
Connection problem with optical block
temperature sensor
Faulty temperature sensor
Connection problem with exhausting
temperature sensor
Faulty temperature sensor
Back cover is not installed.
Replace lamp   Power off after **
min
Clean air filter
Color wheel rotation speed
under 70Hz
Signal processing unit PCB is faulty
Rotation problem with color wheel
DMD drive circuit initializing
error
DMD drive circuit/signal processing block
fault or
bad contact of connectors
FPGA initialized or
communication error
Power fuse 10A 250V
Thermal fuse:
More than 115 degrees Celsius
 (automatic restoration type)
Possible factor
Blown out of the fuse
( with some reason )
Bimetal is OFF (with some reason)
Setting environment confirmation is
required.
Inductor clogging
Something wrong with Ballast block
INF - 17
Page of 71