DP-2310/3010
012 DTMF Level
00 = 0 dBm
~
15 = -15 dBm
Selects the DTMF output level, 0 to -15 dBm in 1 
dBm  steps.
013 G3 RX EQL
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
Selects the cable equalizer for G3 reception mode, 
0dB, 4dB, 8dB or 12dB.
014 G3 TX EQL
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
Selects the cable equalizer for G3 transmission 
mode, 0dB, 4dB, 8dB or 12dB.
015  
016
Not Used
017 TX Start
1 = 2400 bps
2 = 4800 bps
3 = 7200 bps
4 = 9600 bps
5 = TC7200
6 = TC9600
7 = 12000 bps
8 = 14400 bps
Selects the transmission modem start speed, 14400/
12000/TC9600/TC7200/9600/7200/4800/2400 bps.
Note:
This parameter is applicable only when 
communicating with regular G3 machines. When 
communicating with Super G3 (V.34) machines, 
use Parameter No. 32.
018 RX Start
1 = 2400 bps
2 = 4800 bps
3 = 7200 bps
4 = 9600 bps
5 = TC7200
6 = TC9600
7 = 12000 bps
8 = 14400 bps
Selects the reception modem start speed, 14400/
12000/TC9600/TC7200/9600/7200/4800/2400 bps.
Note:
This parameter is applicable only when 
communicating with regular G3 machines. When 
communicating with Super G3 (V.34) machines, 
use Parameter No. 33.
019 ITU-T V.34
1 = Off
2 = On
3 = Select
Selects whether the ITU-T V.34 is Off, On or Select.
Select: Select whether the ITU-T V.34 is Off or On, 
when entering Phone Book Dialing Numbers 
or Manual Number Dialing.
020 ITU-T ECM
1 = Off (Invalid)
2 = On  (Valid)
Select the ECM mode.
021 EP Tone
1 = Off (without EP Tone)
2 = On (with EP Tone)
Selects whether to add the echo protect tone on V.29 
mode.
(Used when Echo Suppression is disabled.)
On : Add
Off : Do not add
022 Signal Interval
1 = 100 ms
2 = 200 ms
3 = 500 ms
Selects the time interval between the receiving 
signal and the transmitting signal.
023 TCF Check
1 = Normal (Short)
2 = Long
Selects the TCF check interval Long/Short
024 CED Frequency 1 = 1080 Hz (non ITU-T)
2 = 2100 Hz
Selects the CED frequency 2100/1080 Hz
025 COMM. Start-Up 1 = First
2 = Second
Selects the communication start-up condition (XMT 
and Polling).
(Used when Echo Suppression is disabled.)
Function Parameter Table
No.
Parameter
Selections
Function
Page of 127
Display

Click on the first or last page to see other DP-2310 / DP-3010 (serv.man4) service manuals if exist.