104
DP-2310/3010
APR 2003
Ver. 1.00
Note 1:  Continuous Polling (Station Mode)
This feature allows you to store or add documents into a polled file in memory. 
To enable the Continuous Polling feature set Function Parameter No. 003 to “2:Station”. 
The last Program Key will be assigned with the “Store 4 Poll” Key name automatically 
and cannot be changed. 
To prepare the document(s) to be polled, simply place the document(s) on the ADF or Platen 
and then press the Program Key to store or add the document(s) into a polled file.
(Note: If a regular polled file is stored in memory, the Program Key for Continuous Polling will 
not be accepted.)
Note 2:  Function Parameter No. 070 (Line Error)-Transmit condition of RTP/PIP or RTN/PIN
Note 3:  Function Parameter No. 071 (Total Error)-Transmit condition of RTP/PIP or RTN/PIN
Note 4: The default setting of parameters depends on the country’s specifications or regulations.  Print the 
Function Parameter List to confirm the default settings.
117
 ~ 
121
Not Used
122 LDAP
1 = Off
2 = On
When LDAP is used, specialize characters may be 
displayed as different characters.
123
 ~ 
174
Not Used
175 FAX/EMAIL
Default
0 = Address Book 
1 = Mode Set
Selects the FAX/EMAIL Default.
176
 ~ 
199
Not Used
Signal
Setting
1:128
2:256
3:512
4:1024
5:2048
6:Off
MCF/PIP
0-31
0-63
0-127
0-255
0-511
Always
RTP/PIP
32-63
64-127
128-255
256-511
512-1023
-
RTN/PIN
64-127
128-255
256-511
512-1023
1024-2047
-
Signal
Setting
1:5%
2:10%
3:15%
4:20%
MCF/PIP
0-2
0-4
0-7
0-9
RTP/PIP
3-4
5-9
8-14
10-19
RTN/PIN
5-
10-
15-
20-
Function Parameter Table
No.
Parameter
Selections
Function
Page of 127
Display