F64:
Gamma data Read /
Write error
Gamma data Read /
Write error
AF 00 00 00 1.Gamma data couldn't be
properly sent to CONTROL
Board via USB interface.
Board via USB interface.
1. Restart the scanner, and then execute
"Carriage Test" in Sec. 9.3.5 to check
whether the same phenomenon is
reproduced.
2. Re-connect the USB cable to the
scanner, and then restart the scanner to
confirm whether the same error occurs.
3. Replace the USB cable.
"Carriage Test" in Sec. 9.3.5 to check
whether the same phenomenon is
reproduced.
2. Re-connect the USB cable to the
scanner, and then restart the scanner to
confirm whether the same error occurs.
3. Replace the USB cable.
2. CONTROL Board does not
work properly.
work properly.
1. Restart the scanner to confirm whether
the same error occurs.
2. Check the soldering condition of ASIC,
and its surrounding circuits on
the CONTROL Board.
3. Replace the CONTROL Board.
the same error occurs.
2. Check the soldering condition of ASIC,
and its surrounding circuits on
the CONTROL Board.
3. Replace the CONTROL Board.
3. The power supply to the
circuit on the CONTROL
Board was interrupted.
circuit on the CONTROL
Board was interrupted.
1. Re-connect the AC Adaptor to the
scanner, and then restart the scanner to
confirm whether the same error occurs.
2. Replace the AC Adaptor.
scanner, and then restart the scanner to
confirm whether the same error occurs.
2. Replace the AC Adaptor.
F65:
CIS in the
Scanning Unit
cannot be turned on.
CIS in the
Scanning Unit
cannot be turned on.
B2 00 00 00 1. Power (+3.3 V) is not
properly supplied to the CIS
included in the Scanning
Unit.
included in the Scanning
Unit.
1. Restart the scanner, and then execute
"Carriage Test" in Sec. 9.3.5 to check
whether the same phenomenon is
reproduced.
2. Check the following connection and
soldering condition on each connector:
(1) J3 (CONTROL Board) to CIS
(2) J2 (CONTROL Board) to AC
Adaptor
3. Replace faulty parts.
"Carriage Test" in Sec. 9.3.5 to check
whether the same phenomenon is
reproduced.
2. Check the following connection and
soldering condition on each connector:
(1) J3 (CONTROL Board) to CIS
(2) J2 (CONTROL Board) to AC
Adaptor
3. Replace faulty parts.
2. The Scanning Unit does not
work properly.
work properly.
1. Check the following connection and
soldering condition on each connector:
soldering condition on each connector:
→ J3 (CONTROL Board) to CIS
2. Replace the Scanning Unit.
3. CONTROL Board does not
work properly.
work properly.
1. Restart the scanner to confirm whether
the same error occurs.
2. Check the soldering condition of ASIC,
and its surrounding circuits on
the CONTROL Board.
3. Replace the CONTROL Board.
the same error occurs.
2. Check the soldering condition of ASIC,
and its surrounding circuits on
the CONTROL Board.
3. Replace the CONTROL Board.
4. The power supply to the
circuit on the CONTROL
Board was interrupted.
circuit on the CONTROL
Board was interrupted.
1. Re-connect the AC Adaptor to the
scanner, and then restart the scanner to
confirm whether the same error occurs.
2. Replace the AC Adaptor.
scanner, and then restart the scanner to
confirm whether the same error occurs.
2. Replace the AC Adaptor.
5. There was a USB
communication error
between PC and CONTROL
Board.
communication error
between PC and CONTROL
Board.
1. Re-connect the USB cable to the
scanner, and then restart the scanner to
confirm whether the same error occurs.
2. Replace the USB cable.
scanner, and then restart the scanner to
confirm whether the same error occurs.
2. Replace the USB cable.
Error Code
Possible Cause
Check Point
Remarks
Classification
Code
ST1 ST2 ST3 ST4